Radiographic Tibial Tunnel Assessment After Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon Autografts and Biocomposite Screws: A Prospective Study With 10-Year Follow-up

Sadesh Balasingam,Ioannis Karikis,Lars Rostgård-Christensen,Mattias Ahldén,Ninni Sernert,Jüri Kartus
DOI: https://doi.org/10.1177/23259671241278340
IF: 2.6
2024-10-19
Orthopaedic Journal of Sports Medicine
Abstract:Orthopaedic Journal of Sports Medicine, Volume 12, Issue 10, October 2024. Background:Biocomposite screws reportedly provide equivalent graft fixation in anterior cruciate ligament reconstruction (ACLR) to metallic screws while simplifying subsequent imaging and surgery. One purported complication of biocomposite screws is paradoxical tunnel widening. Previous studies on beta-tricalcium phosphate screws have only reported outcomes at short- and midterm follow-up.Purpose:To radiographically assess the tibial tunnel 10 years after ACLR using hamstring tendon autografts and biocomposite interference screws in anatomic single-bundle (SB) and double-bundle (DB) methods.Study Design:Case series; Level of evidence, 4.Methods:Of the 105 initially recruited patients, 61 (58%) completed all follow-up evaluations for inclusion in this long-term study. A total of 26 patients received anatomic SB ACLR and 35 patients received DB ACLR with biocomposite interference screws containing beta-tricalcium phosphate in the tibia. Weightbearing anteroposterior and lateral radiographs of the index knee were taken in the early postoperative period and at 2, 5, and 10 years postoperatively; computed tomography (CT) imaging was performed at 10-year follow-up. Subjective and objective clinical assessments were recorded preoperatively and at 10-year follow-up.Results:The mean follow-up period was 122 months. In 76% of radiographs in the SB group, the width of the tibial tunnel had not increased at 10 years compared with the early postoperative period. The mean tibial tunnel volume on CT in the SB group was 2.04 cm3 (± 0.85 cm3). In the DB group, the posterolateral tunnel width had not increased in 69% of radiographs; the same was found in 63% of radiographs for the anteromedial tunnel at 10-year follow-up. The mean posterolateral tunnel volume on CT was 2.04 cm3 (±1.92 cm3) and the mean anteromedial tunnel volume was 1.38 cm3 (±0.54 cm3). There was no correlation between tunnel widths and KT-1000 arthrometer assessments. There was a moderate but statistically significant correlation between SB tibial tunnel volume on CT imaging and KT-1000 arthrometer anterior 134 N side-to-side difference (r = 0.45; P = .039).Conclusion:Most patients' tibial tunnels had not increased on 1 or both radiographic views at 10-year follow-up compared with the early postoperative period after ACLR using biocomposite interference screws, with no obvious negative effect on outcomes. However, the tunnels were still visible in most patients at 10 years on standard radiographs and CT imaging.
orthopedics,sport sciences
What problem does this paper attempt to address?