Monitoring Argatroban Anticoagulation in the Critically Ill: All Tests Are Not Created Equal

Gabor Erdoes,Andreas Koster,Jerrold H. Levy
DOI: https://doi.org/10.1097/aln.0000000000004814
IF: 8.986
2024-01-16
Anesthesiology
Abstract:"While the activated PTT and the whole blood viscoelastic ecarin clotting time showed a modest correlation with mass spectrometry results [( i.e. , argatroban concentrations)], the correlation with the diluted TT was most accurate."
anesthesiology
What problem does this paper attempt to address?