Reducing the Influence of Environmental Factors on Performance of a Diffusion-Based Personal Exposure Kit

Huixin Zong,Peter Brimblecombe,Li Sun,Peng Wei,Kin-Fai Ho,Qingli Zhang,Jing Cai,Haidong Kan,Mengyuan Chu,Wenwei Che,Alexis Kai-Hon Lau,Zhi Ning
DOI: https://doi.org/10.3390/s21144637
IF: 3.9
2021-07-06
Sensors
Abstract:Sensor technology has enabled the development of portable low-cost monitoring kits that might supplement many applications in conventional monitoring stations. Despite the sensitivity of electrochemical gas sensors to environmental change, they are increasingly important in monitoring polluted microenvironments. The performance of a compact diffusion-based Personal Exposure Kit (PEK) was assessed for real-time gaseous pollutant measurement (CO, O3, and NO2) under typical environmental conditions encountered in the subtropical city of Hong Kong. A dynamic baseline tracking method and a range of calibration protocols to address system performance were explored under practical scenarios to assess the performance of the PEK in reducing the impact of rapid changes in the ambient environment in personal exposure assessment applications. The results show that the accuracy and stability of the ppb level gas measurement is enhanced even in heterogeneous environments, thus avoiding the need for data post-processing with mathematical algorithms, such as multi-linear regression. This establishes the potential for use in personal exposure monitoring, which has been difficult in the past, and for reporting more accurate and reliable data in real-time to support personal exposure assessment and portable air quality monitoring applications.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to reduce the impact of environmental factors on the performance of diffusion - based personal exposure kits (PEK) in personal exposure assessment applications. Specifically, the research focuses on how to improve the accuracy and stability of PEK in measuring gaseous pollutants (such as CO, O₃ and NO₂) in complex and changeable environments through dynamic baseline tracking methods and other calibration protocols, especially in the case of rapid changes in temperature and humidity. This helps to avoid using complex mathematical algorithms (such as multiple linear regression) for data post - processing, thereby supporting more accurate and reliable real - time personal exposure assessment and portable air quality monitoring applications. ### Key Points Summary: - **Objective**: Improve the measurement accuracy and stability of PEK in rapidly changing environments. - **Method**: Adopt dynamic baseline tracking methods and a series of calibration protocols. - **Challenge**: The influence of environmental factors (especially temperature and humidity) on electrochemical gas sensors. - **Solution**: Verify the effectiveness of the dynamic baseline tracking method through experiments and compare it with traditional correction algorithms. ### Specific Problems: 1. **Influence of Environmental Factors**: Changes in temperature and humidity can affect the baseline output of the sensor, resulting in inaccurate measurement results. 2. **Linearity of Sensor Response**: It is necessary to verify the linear response of the sensor at different concentrations to ensure its reliability and accuracy. 3. **Response Time**: Evaluate the response time of the sensor to changes in pollutant concentration, especially its performance when temperature and humidity change. 4. **Field Performance**: Verify the performance of PEK in the actual environment, especially its performance in different micro - environments. ### Research Significance: By improving sensor technology, especially the dynamic baseline tracking method, the accuracy and reliability of personal exposure assessment can be improved, which is of great significance for studying the impact of air pollution on human health. In addition, this technology can also be used for portable air quality monitoring to provide real - time data support.