Precisely Controlling the Output Force of Hydrogel Actuator Based on Thermodynamic Nonequilibrium Temporary Deformation

Jincai Yin,Delin Zhang,Zihan Xu,Wenxin Fan,Yanzhi Xia,Kunyan Sui
DOI: https://doi.org/10.1021/acsami.0c13160
2020-10-14
Abstract:Self-shaping hydrogel actuators have promising applications in various fields. However, one hydrogel actuator can generally access only one specifically predefined deformation and output force, which are determined by its thermodynamic equilibrium swelling state under external stimuli. Here, we present a simple yet versatile strategy for precisely programming the output force/energy of dual-gradient hydrogel actuators. The strategy is based on thermodynamic nonequilibrium snapping deformations occurring during the recovery process of predeformed dual-gradient hydrogel actuators in low-temperature water. The output force/energy of such thermodynamic nonequilibrium snapping deformation is highly associated with predeformation conditions of the hydrogel actuators, which increases with the increase of the predeformation temperature or time. In consequence, just by adjusting the predeformation conditions of the dual-gradient hydrogel actuators, their output force, energy, and power can be modulated precisely and continuously during the snapping deformation. The as-prepared hydrogel actuators can not only be used as smart lifters and grippers with ultrahigh accuracy of weight identification but also act as smart switches in the timing circuits with precisely adjustable operating time, paving the way for the design of a new generation of actuation materials.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsami.0c13160?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsami.0c13160</a>.Preparation and characterization of dual-gradient hydrogel actuators, swelling ratio, schematic illustration of the shape transformation, deswelling ratio, weight lifting of dual-gradient actuators, and photographs of the smart switch circuit (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c13160/suppl_file/am0c13160_si_001.pdf">PDF</a>)Shape transformation of the hydrogel actuator in 65 °C water (Movie S1) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c13160/suppl_file/am0c13160_si_002.mp4">MP4</a>)Snapping deformation of the hydrogel actuator in 20 °C water after predeformation at 65 °C for 10 min (Movie S2) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c13160/suppl_file/am0c13160_si_003.mp4">MP4</a>)Lifting of 0.0495 g iron wire in 20 °C water by the hydrogel actuator after predeformation at 65 °C for 6 min (Movie S3) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c13160/suppl_file/am0c13160_si_004.mp4">MP4</a>)Lifting of 0.055 g iron wire in 20 °C water by the hydrogel actuator after predeformation at 65 °C for 6 min (Movie S4) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c13160/suppl_file/am0c13160_si_005.mp4">MP4</a>)Lifting of 0.055 g iron wire in 20 °C water by the hydrogel actuator after predeformation at 65 °C for 8 min (Movie S5) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c13160/suppl_file/am0c13160_si_006.mp4">MP4</a>)Lifting of 0.055 g iron wire in 20 °C water by the hydrogel actuator after predeformation at 65 °C for 14 min (Movie S6) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c13160/suppl_file/am0c13160_si_007.mp4">MP4</a>)Lifting of 1.9 g object in 20 °C water by the T-shaped hydrogel actuator after predeformation at 65 °C for 12 min (Movie S7) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c13160/suppl_file/am0c13160_si_008.mp4">MP4</a>)Lifting of 1.9 g object in 20 °C water by the T-shaped hydrogel actuator after predeformation at 65 °C for 10 min (Movie S8) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c13160/suppl_file/am0c13160_si_009.mp4">MP4</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology
What problem does this paper attempt to address?