MRI characteristics of breast ductal carcinoma in situ
Yingming Cao,Bo Zhou,Fei Xie,Miao Liu,Shu Wang,Houpu Yang,Fei Yuan,Nan Hong
DOI: https://doi.org/10.3760/cma.j.issn.1673-4777.2014.03.022
2014-01-01
Abstract:Objective To investigate the magnetic resonance imaging (MRI) characteristics of breast ductal carcinoma in situ (DCIS). Methods A retrospective analysis of MRI features in 80 breast DCIS patients was performed according to breast imaging reporting and data system (BI-RADS). Results Thirty-one patients were diagnosed benign by MRI, 49 cases were diagnosed malignancy. Of the 20 mass-like lesions, 7 cases (35.0%) were round, 6 cases (30.0%) were lobulated, 7 cases (35.0%) were irregular. The coincidence rate of MRI in detecting mass-like and non-mass-like lesions was 80.0% and 55.0% (P<0.05), respectively. Seven cases (35.0%) had distinct margins, 12 cases (60.0%) had indistinct margins and 1 case (5.0%) had spiculated margins. Seven cases (35.0%) showed internal homogeneous enhancement, 7 cases (35.0%) had ring enhancement and 6 cases (30.0%) had septal enhancement. TypeⅠ, Ⅱ, and Ⅲ time-signal intensity curve (TIC) was identified in 3,9 and 8 lesions, respectively. 6 cases(10.0%) were homogeneous enhancement, 24 cases (40.0%) were heterogeneous enhancement, 3 cases (5.00%) were punctate enhancement and 27 cases (45.0%) were clumped enhancement. TypeⅠ, Ⅱ, and Ⅲ TIC was observed in 20, 31 and 9 lesions, respectively. Conclusion MRI is effective on detecting mass-like lesions. In non-mass-like lesions, clumped or heterogeneous enhancement of segmental or regional lesion is the main MRI feature.