Device-Associated Infection Rates in 20 Cities of India, Data Summary for 2004-2013: Findings of the International Nosocomial Infection Control Consortium
Yatin Mehta,Namita Jaggi,Victor Daniel Rosenthal,Maithili Kavathekar,Asmita Sakle,Nita Munshi,Murali Chakravarthy,Subhash Kumar Todi,Narinder Saini,Camilla Rodrigues,Karthikeya Varma,Rekha Dubey,Mohammad Mukhit Kazi,F E Udwadia,Sheila Nainan Myatra,Sweta Shah,Arpita Dwivedy,Anil Karlekar,Sanjeev Singh,Nagamani Sen,Kashmira Limaye-Joshi,Bala Ramachandran,Suneeta Sahu,Nirav Pandya,Purva Mathur,Samir Sahu,Suman P Singh,Anil Kumar Bilolikar,Siva Kumar,Preeti Mehta,Vikram Padbidri,N Gita,Saroj K Patnaik,Thara Francis,Anup R Warrier,S Muralidharan,Pravin Kumar Nair,Vaibhavi R Subhedar,Ramachadran Gopinath,Afzal Azim,Sanjeev Sood
DOI: https://doi.org/10.1017/ice.2015.276
Abstract:Objective: To report the International Nosocomial Infection Control Consortium surveillance data from 40 hospitals (20 cities) in India 2004-2013. Methods: Surveillance using US National Healthcare Safety Network's criteria and definitions, and International Nosocomial Infection Control Consortium methodology. Results: We collected data from 236,700 ICU patients for 970,713 bed-days Pooled device-associated healthcare-associated infection rates for adult and pediatric ICUs were 5.1 central line-associated bloodstream infections (CLABSIs)/1,000 central line-days, 9.4 cases of ventilator-associated pneumonia (VAPs)/1,000 mechanical ventilator-days, and 2.1 catheter-associated urinary tract infections/1,000 urinary catheter-days In neonatal ICUs (NICUs) pooled rates were 36.2 CLABSIs/1,000 central line-days and 1.9 VAPs/1,000 mechanical ventilator-days Extra length of stay in adult and pediatric ICUs was 9.5 for CLABSI, 9.1 for VAP, and 10.0 for catheter-associated urinary tract infections. Extra length of stay in NICUs was 14.7 for CLABSI and 38.7 for VAP Crude extra mortality was 16.3% for CLABSI, 22.7% for VAP, and 6.6% for catheter-associated urinary tract infections in adult and pediatric ICUs, and 1.2% for CLABSI and 8.3% for VAP in NICUs Pooled device use ratios were 0.21 for mechanical ventilator, 0.39 for central line, and 0.53 for urinary catheter in adult and pediatric ICUs; and 0.07 for mechanical ventilator and 0.06 for central line in NICUs. Conclusions: Despite a lower device use ratio in our ICUs, our device-associated healthcare-associated infection rates are higher than National Healthcare Safety Network, but lower than International Nosocomial Infection Control Consortium Report.