MRI Deep Learning-Based Automatic Segmentation of Interventricular Septum for Black-Blood Myocardial T2* Measurement in Thalassemia.

Bingquan Lin,Yanqiu Feng,Lingjian Chen,Zifeng Lian,Qiqi Lu,Peng Peng
DOI: https://doi.org/10.1002/jmri.29113
IF: 4.4
2023-11-09
Journal of Magnetic Resonance Imaging
Abstract:BACKGROUND The T2* value of interventricular septum is routinely reported for grading myocardial iron load in thalassemia major, and automatic segmentation of septum could shorten analysis time and reduce interobserver variability. PURPOSE To develop a deep learning-based method for automatic septum segmentation from black-blood MR images for the myocardial T2* measurement of thalassemia patients. STUDY TYPE Retrospective. POPULATION/SUBJECTS One hundred forty-six transfusion-dependent thalassemia patients with cardiac MR examinations from two centers. Data from Center 1 (1.5 T) were assigned to the training (100 examinations) and internal testing (20 examinations) sets; data from Center 2 were assigned to the external testing set (26 examinations; 10 at 1.5 T and 16 at 3.0 T). FIELD STRENGTH/SEQUENCE 1.5 T and 3.0 T, multiecho gradient-echo sequence. ASSESSMENT A modified attention U-Net for septum segmentation was constructed and trained, and its performance evaluated on unseen internal and external datasets. T2* was measured by fitting the average septum signal, separately segmented by automatic and manual methods. STATISTICAL TESTS Agreement between manual and automatic septum segmentations was assessed with the Dice coefficient, and T2* agreement was assessed using the Bland-Altman plot and the coefficient of variation (CoV). RESULTS The median Dice coefficient of deep network-based septum segmentation was 0.90 [0.05] on the internal dataset, 0.82 [0.10] on the external 1.5 T dataset, and 0.86 [0.14] on the external 3.0 T dataset. T2* measurements using automatic segmentation corresponded with those from manual segmentation, with a mean difference of 0.02 (95% LoA: -0.74 to 0.79) msec, 0.43 (95% LoA: -2.1 to 3.0) msec, and 0.36 (95% LoA: -0.72 to 1.4) msec on the three datasets. The CoVs between the two methods were 3.1%, 7.0%, and 6.1% on the internal and two external datasets, respectively. DATA CONCLUSIONS The proposed septum segmentation yielded myocardial T2* measurements which were highly consistent with those obtained by manual segmentation. This automatic approach may facilitate data processing and avoid operator-dependent variability in practice. EVIDENCE LEVEL 4 TECHNICAL EFFICACY: Stage 1.
Medicine
What problem does this paper attempt to address?