Benzoic acid/nanocellulose incorporated low-pressure hollow fiber membranes for effective natural organic matter removal: Understanding the fouling mechanisms and cleaning strategies

Phumlile P. Mamba,Titus A.M. Msagati,Bhekie B. Mamba,Machawe M. Motsa,Thabo T.I. Nkambule
DOI: https://doi.org/10.1016/j.jwpe.2024.105448
IF: 7
2024-05-24
Journal of Water Process Engineering
Abstract:Residual natural organic matter (NOM) in drinking water treatment reacts with chlorine-based disinfectants to form carcinogenic disinfection by-products. Membrane filtration has become an alternative method for NOM removal, however, its accumulation on the membrane surface leads to fouling which lowers plant performance. This study evaluated the performance of low-pressure hollow fiber (HF) membranes in removing NOM from surface water sources from the Limpopo and Gauteng provinces, South Africa. The prepared membranes were characterized using microscopic and spectroscopic techniques. The cross-sectional images of the membranes exhibited an elongated finger-like structure whilst, the water contact angle and pure water flux of the 0 cm airgap distance-optimized membranes indicated an increase in hydrophilicity. Moreover, FTIR results confirmed the attachment of 4-hydroxybenzoic acid (HBA) and nanocellulose on the membranes. The highest NOM removal, 97.7 % in terms of UV 254 was achieved by HBA-HF3 membrane when filtering river water. Moreover, the HBA-HF4 membrane effectively removed 75 % humic-like fraction which suggests that size exclusion was the major removal mechanism. Only a 1.7 % permeate flux decline was recorded after 180 min filtration by the best-performing membrane HBA-HF4. A 98.6 % initial flux was recovered after physical flushing with 0.1 % NaOCl solution due to the lack of fouling layer compression. Intermediate irreversible fouling was dominant in the prolonged fouling experiment with a 40 % decline in permeate flux due to the accumulation of humic-like substances forming a cake layer on the membrane surface, however, 79.2 % was recovered after membrane cleaning. The low fouling rate of the membranes was due to enhanced membrane surface hydrophilicity and the effectiveness of the cleaning solution. These fundamental results demonstrated that porous HF membranes can be effective chemical-free alternatives for enhanced removal of NOM while retarding membrane fouling.
engineering, chemical, environmental,water resources
What problem does this paper attempt to address?