Methane emissions from residential natural gas meter set assemblies

Coleman Vollrath,Chris H. Hugenholtz,Thomas E. Barchyn,Clay Wearmouth
DOI: https://doi.org/10.1016/j.scitotenv.2024.172857
IF: 9.8
2024-05-10
The Science of The Total Environment
Abstract:Residential natural gas meter set assemblies (MSAs) emit methane (CH 4 ), but reported emissions factors vary. To test existing emissions factors, we quantified CH 4 emissions from 37 residential MSAs in Calgary, Alberta, Canada. A notable difference with previous studies is the targeted measurement of regulator vents in this study, which were measured with a static chamber, while fugitives were measured with a modified hi-flow sampler. Emissions were dominated by pressure regulator vents (emissions factor = 1.18 g CH 4 /h/MSA), but 7 fugitives were found (emissions factor = 0.018 g CH 4 /h/MSA). Six regulator vents were emitting at notably higher rates (≥ 1.79 g CH 4 /h/MSA). The total empirical emissions factor was 1.20 g CH 4 /h/MSA (95 % CI, 1.03 to 1.37 g/h/MSA). This is ∼7 times higher than the emissions factor for residential MSAs used in the U.S. EPA's Greenhouse Gas Inventory, which may not include emissions from regulator vents. Upscaling to annual CH 4 emissions in Calgary indicates 3234.6 t CH 4 /yr (95 % CI, 2776.4 t to 3692.9 t CH 4 /yr) could be emitted from MSAs. This is equivalent to 4.1 % (95 % CI, 3.5 % to 4.7 %) of total city-level CH 4 emissions as estimated with satellite data. Results suggest residential MSA emissions may be under-estimated and further study isolating root causes of regulator vent emissions is required to guide mitigation and improve emissions modeling.
environmental sciences
What problem does this paper attempt to address?