Image-Guided Embolization Coil Placement for Identification of an Endophytic, Isoechoic Renal Mass During Robotic Partial Nephrectomy

James Jeffery Reeves,Andrew Forauer,John D Seigne,Elias S Hyams
DOI: https://doi.org/10.1089/cren.2015.0022
2015-11-01
Abstract:Background: Intraoperative ultrasonography has proven to be a useful tool for tumor identification during robot-assisted laparoscopic partial nephrectomy (RALPN). However, its utility is limited in renal tumors that are completely endophytic and isoechoic in nature. We present a novel approach to intraoperative tumor identification using preoperative percutaneous intratumoral embolization coil placement that may be utilized in the management of such cases. Case presentation: A 42-year-old Caucasian male was referred with an incidentally discovered right renal mass that was posterior and completely endophytic. He desired a RALPN; however, preoperative renal ultrasound demonstrated an isoechoic lesion. Thus, the patient underwent preoperative image-guided placement of an embolization coil within the tumor. This facilitated identification of the tumor intraoperatively using intracorporeal ultrasound centered on the coil and enabled resection with negative margins. Conclusion: Utilizing a novel approach analogous to preoperative localization of other solid malignancies, such as breast cancer, we were able to effectively identify and resect an isoechoic renal mass during RALPN.