Lung herniation in the implantable cardioverter defibrillator pocket

Mashrafi Ahmed,T. Begum
DOI: https://doi.org/10.1136/bcr-2015-210703
2015-07-03
BMJ Case Reports
Abstract:A 47-year-old Caucasian man with the medical history of hypertension, hypercholesterolaemia and non-ischaemic cardiomyopathy with ejection fraction (EF) of 25–30% presented with pain in the left upper chest wall. Nearly 2 months earlier, he had undergone implantable cardioverter defibrillator (ICD) placement surgery for low EF. The initial attempt to place the biventricular lead was unsuccessful. Subsequently, he had epicardial lead placement performed by the cardiothoracic surgeon with repositioning of the ICD generator above the previous pocket. One week prior, he noticed a small bulging over the area of recent surgery, particularly during coughing. It got worse and, the day prior …