Precursors of Halobenzoquinones and Their Removal During Drinking Water Treatment Processes

Wei Wang,Yichao Qian,Lindsay K Jmaiff,Stuart W Krasner,Steve E Hrudey,Xing-Fang Li
DOI: https://doi.org/10.1021/acs.est.5b02308
2015-08-18
Abstract:Halobenzoquinones (HBQs) widely occur in drinking water treatment plant (DWTP) effluents; however, HBQ precursors and their removal by treatments remain unclear. Thus, we have investigated HBQ precursors in plant influents and their removal by each treatment before chlorination in nine DWTPs. The levels of HBQ precursors were determined using formation potential (FP) tests for 2,6-dichloro-1,4-benzoquinone (DCBQ), 2,3,6-trichloro-1,4-benzoquinone (TCBQ), 2,6-dichloro-3-methyl-1,4-benzoquinone (DCMBQ), and 2,6-dibromo-1,4-benzoquinone (DBBQ). HBQ precursors were present in all plant influents. DCBQ precursors were the most abundant (DCBQ FP up to 205 ng/L). Coagulation removed dissolved organic carbon (DOC) (up to 56%) and HBQ precursors (up to 39% for DCBQ). The level of removal of DOC was significantly greater than the level of removal of HBQ FP, suggesting that organic matter removed by coagulation had a high proportion of non-HBQ-precursor material. Granular activated carbon (GAC) decreased the level of HBQ FPs by 10-20%, where DOC removal was only 0.2-4.7%, suggesting that the GAC was not in the adsorption mode and biodegradation of HBQ precursors may have been occurring. Ozonation destroyed/transformed HBQ FPs by 10-30%, whereas anthracite/sand filtration and UV irradiation appeared to have no impact. The results demonstrated that the combined treatments did not substantially reduce HBQ precursor levels in water.
What problem does this paper attempt to address?