Quantitative in situ and real-time monitoring of mechanochemical reactions

Ivan Halasz,Tomislav Friščić,Simon A J Kimber,Krunoslav Užarević,Andreas Puškarić,Cristina Mottillo,Patrick Julien,Vjekoslav Strukil,Veijo Honkimäki,Robert E Dinnebier
DOI: https://doi.org/10.1039/c4fd00013g
Abstract:An experimental technique for in situ and real-time monitoring of mechanochemical reactions in a shaker ball mill was recently described, which utilises highly penetrating X-ray radiation available at the ID15B beamline of the European Synchrotron Radiation Facility. Herein, we describe the first attempts to perform such reaction monitoring in a quantitative fashion, by introducing an internal X-ray diffraction standard. The use of silicon as an internal standard resolved the issue with variations of the amount of the sample in the X-ray beam due to the non-uniform distribution of the sample in the reaction jar and allowed, via Rietveld analysis, the first quantitative estimate of the amorphous phase content in a mechanochemical reaction as it is being milled. We also highlight problems associated with the non-ideal mixing of the reaction mixture.
What problem does this paper attempt to address?