Static Compliance After Lung Transplantation And Early Mortality
Cecilia Veraar,Stefan Schwarz,Peter Wohlrab,Johannes Geilen,Thomas Neugebauer,Konrad Hoetzenecker,Marcus J.J. Schultz,Martin Dworschak,Edda Tschernko
DOI: https://doi.org/10.1053/j.jvca.2024.09.080
IF: 2.894
2024-10-27
Journal of Cardiothoracic and Vascular Anesthesia
Abstract:Objective Primary graft dysfunction of the transplanted lung still is a serious problem and greatly impacts outcome. Despite medical and technological progress, primary graft dysfunction continues to be a leading cause of morbidity and mortality in recipients, necessitating early intervention. Assessment of lung function post-transplantation, particularly static compliance, emerges as a promising indicator of short-term outcomes. We, therefore, investigated whether static compliance determined immediately after lung transplantation for end-stage pulmonary failure is predictive of 30-day mortality. Design and method In this single-centre retrospective investigation we analysed data from 755 consecutive patients who underwent orthotopic lung-transplantation between the years 2014 and 2023. The primary endpoint was 30-day mortality. Patients older than 18 years of age undergoing lung transplantation were eligible for inclusion. Patients who underwent single lung transplantation, multi-organ transplantation, or re-transplantation were excluded from the analysis. Respiratory parameters for calculating static compliance were collected after chest closure and muscle relaxation at the end of surgery. Lung-protective ventilation strategies were applied whenever feasible. Univariate and multivariate analyses were conducted and Receiver Operating Characteristic curves constructed. Results and conclusions ResultsTwo hours after surgery, 695 of the 755 patients (65%), were classified as having primary graft dysfunction grade 0, 30 patients (4%) were classified as grade 1, 40 patients (5%) received a grade 2 classification, 91 patients (12%) a grade 3, and 85 patients (11%) were categorized as ungradable. In this huge cohort we observed a thirty-day mortality of 1.9%. Increased static compliance was predictive for 30-day survival with an acceptable area under the curve of 0.735 (95% CI: 0.5-0.9; p=0.003). Moreover, a static compliance below 25 mL/mbar had a statistically increased hazard ratio of 6.0 (95% CI: 1.3-27.0; P=0.005) for 30-day mortality. Conclusions As determined in this study, static compliance measured immediately after lung transplantation could serve as a predictive marker for short-term outcome. Integrating this measure into clinical practice could potentially improve risk stratification and guide early interventions. Nevertheless, further prospective studies are needed for validation of this data and for a better understanding of the underlying pathophysiology.
cardiac & cardiovascular systems,peripheral vascular disease,respiratory system,anesthesiology