Transition Boundary from Laminar to Turbulent Flow of Microencapsulated Phase Change Material Slurry—Experimental Results
Krzysztof Dutkowski,Marcin Kruzel,Martyna Kochanowska
DOI: https://doi.org/10.3390/ma17246041
IF: 3.4
2024-12-11
Materials
Abstract:An ice slurry or an emulsion of a phase change material (PCM) is a multiphase working fluid from the so-called Latent Functional Thermal Fluid (LFTF) group. LFTF is a fluid that uses, in addition to specific heat, the specific enthalpy of the phase change of its components to transfer heat. Another fluid type has joined the LFTF group: a slurry of encapsulated phase change material (PCM). Technological progress has made it possible for the phase change material to be enclosed in a capsule of the size of the order of micrometers (microencapsulated PCM—mPCM) or nanometers (nanoencapsulated PCM—nPCM). This paper describes a method for determining the Reynolds number (Re) at which the nature of the flow of the mPCM slurry inside a straight pipe changes. In addition, the study results of the effect of the concentration of mPCM in the slurry and the state of the PCM inside the microcapsule on the value of the critical Reynolds number (Recr) are presented. The aqueous slurry of mPCM with a concentration from 4.30% to 17.20% wt. flowed through a channel with an internal diameter of d = 4 mm with a flow rate of up to 110 kg/h (Re = 11,250). The main peak melting temperature of the microencapsulated paraffin wax used in the experiments was around 24 °C. The slurry temperature during the tests was maintained at a constant level. It was 7 °C, 24 °C and 44 °C (the PCM in the microcapsule was, respectively, a solid, underwent a phase change and was a liquid). The experimental studies clearly show that the concentration of microcapsules in the slurry and the state of the PCM in the microcapsule affect the critical Reynolds number. The higher the concentration of microcapsules in the slurry, the more difficult it was to maintain laminar fluid flow inside the channel. Furthermore, the laminar flow of the slurry terminated at a lower critical Reynolds number when the PCM in the microcapsule was solid. Caution is advised when choosing the relationship to calculate the flow resistance or heat transfer coefficients, because assuming that the flow motion changes at Re = 2300, as in the case of pure liquids, may be an incorrect assumption.
materials science, multidisciplinary,chemistry, physical,physics, applied, condensed matter,metallurgy & metallurgical engineering