Associations between size-fractioned particulate matter and left ventricular voltage: A panel study among healthy young adults in southern China

Dan Feng,Ke Cao,Jun Zou,Michael S. Bloom,Shao Lin,Yunjiang Yu,Hongyao Yu,Yang Zhou,Ru-Qing Liu,Li-Wen Hu,Bo-Yi Yang,Xiao-Wen Zeng,Guang-Hui Dong
DOI: https://doi.org/10.1016/j.atmosenv.2021.118395
IF: 5
2021-06-01
Atmospheric Environment
Abstract:<p>Exposure to ambient air pollution is consistently associated with increased cardiovascular morbidity and mortality; however, the underlying pathophysiologic mechanisms remain unclear. High left ventricular voltage has been related to cardiac dysfunction.Therefore, this study aimed to investigate the association between longitudinal exposure to size-fractioned particulate matter (PM) and left ventricular voltage (assessed as the sum of the voltages of the R-wave in lead V5 [RV5] and S-wave in lead V1[SV1]) among 88 healthy, young Chinese adults. We collected weekly 12-lead electrocardiogram (ECG) and serum biomarkers from each participant five times over 35 days. The fixed point, real-time, mass concentrations of particles with aerodynamic diameters of ≤ 2.5 μm (PM<sub>2.5</sub>), PM<sub>1</sub>, PM<sub>0.5</sub>, and number concentrations of particles with aerodynamic diameters of ≤ 0.2 μm (PNC<sub>0.2</sub>), PNC<sub>0.1</sub>, and PNC<sub>0.03</sub> were monitored in the catchment area, and linear mixed-effect models were used to estimate the associations between the size-fractioned PM exposure and ECG indices. The results showed that there was a significant association between higher size-fractioned PM levels and higher RV5+SV1 voltage within 24 h of exposure. We detected increases in the RV5+SV1 voltage of 0.060, 0.058, 0.090, 0.084, and 0.077 mV per interquartile range (IQR) PM<sub>2.5</sub> (45.92 μg/m<sup>3</sup>; 95% confidence interval [CI] = 0.003, 0.117), PM<sub>1</sub> (43.51 μg/m<sup>3</sup>; 95% CI = 0.003, 0.113), PNC<sub>0.2</sub> (14.92×10<sup>3</sup> particles/cm<sup>3</sup>; 95% CI = 0.017, 0.163), PNC<sub>0.1</sub> (12.79×10<sup>3</sup> particles/cm<sup>3</sup>; 95% CI = 0.004, 0.163), and PNC<sub>0.03</sub> (5.43×10<sup>3</sup> particles/cm<sup>3</sup>; 95% CI = 0, 0.153), respectively. The associations between the RV5+SV1 voltage and size-fractioned PM exposure were stronger among participants with greater serum concentrations of monocyte chemoattractant protein-1, soluble CD40 ligand, plasminogen activator inhibitor-1, and total cholesterol, and lower high-density lipoprotein cholesterol levels. Exposure to various PM size fractions (PNC<sub>0.03</sub>-PNC<sub>0.2</sub>, and PM<sub>0.5</sub>-PM<sub>2.5</sub>) may increase the left ventricular voltage among healthy young adults, and the effects may be modified by inflammation, coagulation, and lipid biomarkers.</p>
environmental sciences,meteorology & atmospheric sciences
What problem does this paper attempt to address?