Auto-calibrated Wearable System for Load Vertical Location Estimation During Manual Lifting

Diliang Chen,Nozhan Ghoreishi,John LaCourse,Sajay Arthanat,Dain LaRoche
2024-11-25
Abstract:Lifting during manual material handling is a major cause of low-back pain (LBP). As an important risk factor that directly influences the risk of LBP, the Load vertical location (LVL) during lifting needs to be measured and controlled. However, existing solutions for LVL measurement are inefficient, inaccurate, and impractical for real-world workplace environments. To address these problems, an unobtrusive wearable system, including smart insoles and smart wristbands, was proposed to measure LVL accurately in workplace environments. Different from traditional methods which rely on Inertial Measurement Unit (IMU) and suffer from integral drifting errors over time, a novel barometer-based LVL measurement method was proposed in this study. To correct the environment-induced LVL measurement errors in the barometer-based method, a novel Known Vertical Location Update (KVLU) method was proposed. This method calibrates the measured LVL using a known wrist vertical location at known postures during frequently used daily activities such as standing and walking. The proposed wearable system achieved a mean absolute error (MAE) of 5.71 cm in LVL measurement. This result indicates that the proposed system has the potential to reliably measure LVL and assess the risk of LBP in manual lifting tasks.
Human-Computer Interaction
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: during the process of manually transporting materials, how to accurately measure and control the load vertical level (LVL) in order to assess and reduce the risk of low back pain (LBP). Specifically: 1. **Limitations of existing methods**: - **Observation method**: Although observations conducted by professional ergonomics experts are commonly used, they are time - consuming and prone to subjective errors. - **Computer vision method**: Although it can accurately track LVL, it is not practical in the presence of complex lighting conditions and obstacles, and is costly. - **Wearable devices based on inertial measurement units (IMU)**: Due to integral drift errors and the need to wear multiple sensors, it affects the user experience and long - term accuracy. 2. **Research objectives**: - Propose a non - intrusive wearable system, including smart insoles and smart bracelets, for accurately measuring LVL in the work environment. - Solve the environmental drift problem in barometer measurement and ensure the accuracy of long - term measurement. 3. **Solutions**: - **Hardware design**: Use smart insoles and smart bracelets, which are connected to smartphone applications via Bluetooth to collect and analyze data in real - time. - **Calibration method**: Propose a self - calibration method based on known vertical level update (KVLU), using known postures in daily activities (such as standing and walking) to correct measurement errors. 4. **Contributions**: - Developed a user - friendly and reliable wearable system that can accurately measure LVL for a long time in an uncontrolled work environment. - Proposed the KVLU self - calibration method, which effectively corrects drift errors by fusing gait, posture and anthropometric data. - Verified the performance of the system through experiments, and the results show that the mean absolute error (MAE) is 5.71 cm. Through these improvements, this research aims to provide a practical and accurate method to help assess and reduce the LBP risk in manual handling tasks.