SENSEI at SNOLAB: Single-Electron Event Rate and Implications for Dark Matter

Itay M. Bloch,Ana M. Botti,Mariano Cababie,Gustavo Cancelo,Brenda A. Cervantes-Vergara,Miguel Daal,Ansh Desai,Alex Drlica-Wagner,Rouven Essig,Juan Estrada,Erez Etzion,Guillermo Fernandez Moroni,Stephen E. Holland,Jonathan Kehat,Ian Lawson,Steffon Luoma,Aviv Orly,Santiago E. Perez,Dario Rodrigues,Nathan A. Saffold,Silvia Scorza,Miguel Sofo-Haro,Kelly Stifter,Javier Tiffenberg,Sho Uemura,Edgar Marrufo Villalpando,Tomer Volansky,Federico Winkel,Yikai Wu,Tien-Tien Yu
2024-10-24
Abstract:We present results from data acquired by the SENSEI experiment at SNOLAB after a major upgrade in May 2023, which includes deploying 16 new sensors and replacing the copper trays that house the CCDs with a new light-tight design. We observe a single-electron event rate of $(1.39 \pm 0.11) \times 10^{-5}$ e$^-$/pix/day, corresponding to $(39.8 \pm 3.1)$ e$^-$/gram/day. This is an order-of-magnitude improvement compared to the previous lowest single-electron rate in a silicon detector and the lowest for any photon detector in the near-infrared-ultraviolet range. We use these data to obtain a 90% confidence level upper bound of $1.53 \times 10^{-5}$ e$^-$/pix/day and to set constraints on sub-GeV dark matter candidates that produce single-electron events. We hypothesize that the data taken at SNOLAB in the previous run, with an older tray design for the sensors, contained a larger rate of single-electron events due to light leaks. We test this hypothesis using data from the SENSEI detector located in the MINOS cavern at Fermilab.
Cosmology and Nongalactic Astrophysics,High Energy Physics - Experiment
What problem does this paper attempt to address?