Characterizing the Effect of Electrode Shift & Sensor Reapplication on Common sEMG Features in Lower Limb Muscles

Fraser Douglas,Mona Pei,Calvin Kuo
2024-10-22
Abstract:This study investigates the impact of electrode shift and sensor reapplication on common surface electromyography (sEMG) features in lower limb muscles, factors which have, thus far, precluded clinicians from being able to attribute inter-session changes in sEMG signal properties to physiological changes in patients under the context of stroke recovery monitoring. To explore these inter-session errors, we recruited 12 healthy participants to perform a selection of isometric and dynamic exercises seen within stroke assessment sessions while instrumented with high-density sEMG (HDsEMG) arrays on the gastrocnemius medialis, tibialis anterior, semitendinosus, and tensor fascia latae. Between exercise sets, the electrode arrays were intentionally shifted and reapplied to quantify errors in signal features, using 3D scanning equipment to extract the ground truth shift performed. Results revealed that while frequency-domain features (mean, median, and peak frequency) demonstrated high resilience to the inter-session changes, the time-domain features (integrated EMG and max envelope amplitude) showed a greater, yet predictable, variability. In all, these findings suggest that should we be able to quantify placement shift, this can support direct inter-session feature comparisons, improving the reliability of sEMG-based stroke recovery assessments and offering insights for improving remote stroke rehabilitation technologies.
Signal Processing
What problem does this paper attempt to address?
The problems that this paper attempts to solve are: **The effects of electrode displacement and sensor re - application on the characteristics of surface electromyography (sEMG) signals of lower - limb muscles, and how to quantify these effects to improve the reliability of stroke rehabilitation assessment.** Specifically, the authors focus on: 1. **The problem of attributing cross - session changes**: In stroke rehabilitation monitoring, due to changes in electrode positions and skin - electrode interfaces, clinicians are unable to directly attribute changes in sEMG signal properties across sessions to patients' physiological changes. 2. **The need for remote rehabilitation assessment**: With the development of telemedicine, especially during the COVID - 19 pandemic, remote assessment has become increasingly important. However, remote assessment depends on the quality of video conferencing and the stability of the Internet, which increases subjectivity. Therefore, more objective methods are needed to support remote stroke rehabilitation assessment. 3. **Quantifying the effects of electrode displacement**: In order to accurately compare sEMG characteristics between different sessions, it is necessary to be able to quantify the effects of electrode displacement. This can ensure the reliability of cross - session feature comparison, thereby better tracking patients' rehabilitation progress. ### Main research questions 1. **Can the difference in feature values be expressed as a function of distance?** - Researchers hope to understand whether the changes in sEMG feature values are related to the distance of electrode displacement. 2. **What is the error caused by removing and re - applying the sensor array?** - Through experimental design, researchers hope to quantify the error introduced when the sensor is re - applied. 3. **How do these errors combine?** - Researchers hope to understand the error situation under the combined action of electrode displacement and sensor re - application through analysis. ### Method overview To answer these questions, researchers carried out the following steps: 1. **Recruit healthy participants**: 12 healthy participants were recruited to conduct a series of isometric and dynamic exercise tests. 2. **Use high - density sEMG electrode arrays**: High - density sEMG electrode arrays were installed on the medial head of the gastrocnemius, the tibialis anterior, the semitendinosus, and the tensor fasciae latae. 3. **Experimental protocol**: Before and after each exercise, the electrode arrays of the participants would be intentionally displaced and re - applied to quantify the changes in signal characteristics. 4. **3D scanning to determine the real displacement**: A 3D scanning device was used to record the real displacement of the electrode arrays. 5. **Feature extraction and analysis**: Time - domain and frequency - domain features were extracted from sEMG data, and the changes of these features with electrode displacement were analyzed. ### Results and conclusions The research results show that: - **Frequency - domain features (such as mean frequency, median frequency, and peak frequency) show higher robustness to cross - session changes**, while time - domain features (such as integrated EMG and maximum envelope amplitude) show greater but predictable variability. - **By quantifying electrode displacement, direct comparison of cross - session features can be supported to a certain extent**, thereby improving the reliability of sEMG - based stroke rehabilitation assessment. - **Frequency - domain features are more suitable for cross - session comparison than time - domain features because they are insensitive to signal amplitude attenuation. These findings are helpful for improving remote stroke rehabilitation techniques and providing more reliable quantitative assessment methods.