Deposition simulations of realistic dosages in patient-specific airways with two- and four-way coupling

Josh Williams,Jose Manuel Menendez Montes,Steve Cunningham,Uwe Wolfram,Ali Ozel
2024-09-23
Abstract:Inhalers spray over 100 million drug particles into the mouth, where a significant portion of the drug may deposit. Understanding how the complex interplay between particle and solid phases influence deposition is crucial for optimising treatments. Existing modelling studies neglect any effect of particle momentum on the fluid (one-way coupling), which may cause poor prediction of forces acting on particles. In this study, we simulate a realistic number of particles (up to 160 million) in a patient-specific geometry. We study the effect of momentum transfer from particles to the fluid (two-way coupling) and particle-particle interactions (four-way coupling) on deposition. We also explore the effect of tracking groups of particles (`parcels') to lower computational cost. Upper airway deposition fraction increased from 0.33 (one-way coupled) to 0.87 with two-way coupling and $10 \mu m$ particle diameter. Four-way coupling lowers upper airway deposition by approximately 10% at $100 \mu g$ dosages. We use parcel modelling to study deposition of $4 - 20 \mu m$ particles, observing significant influence of two-way coupling in each simulation. These results show that future studies should model realistic dosages for accurate prediction of deposition which may inform clinical decision-making.
Medical Physics
What problem does this paper attempt to address?
The main issues this paper attempts to address are: 1. **Assessing the impact of two-phase coupling and four-phase coupling**: Investigating the effects of two-phase coupling (momentum transfer between fluid and particles) and four-phase coupling (interactions between particles) on deposition when simulating actual dosage drug particles (up to 160 million particles). 2. **Validating the effectiveness of the parcel-based simulation method**: Exploring the method of using "parcels" that represent multiple particles to reduce computational costs and verifying the accuracy of this method under different parcel quantities. Through these studies, the paper aims to reveal more accurate drug deposition prediction methods to optimize patient treatment plans. Specifically, the research found that two-phase coupling significantly increased the deposition ratio in the upper respiratory tract, while four-phase coupling further reduced this ratio. Additionally, the study analyzed the impact of different parcel quantities on simulation results, finding that when each parcel contains more than 1000 particles, the error becomes unacceptable.