Super-Heisenberg scaling in a triple point criticality

Jia-Ming Cheng,Yong-Chang Zhang,Xiang-Fa Zhou,Zheng-Wei Zhou
2024-09-21
Abstract:We investigate quantum-enhanced metrology in a triple point criticality and discover that quantum criticality can not always enhance measuring precision. We have developed suitable adiabatic evolution protocols approaching a final point around the triple point to effectively restrain excitations, which could accelerate the adiabatic evolutions and lead to an exponential super-Heisenberg scaling. This scaling behavior is quite valuable in practical parameter estimating experiments with limited coherence time. The super-Heisenberg scaling will degrade into a sub-Heisenberg scaling if the adiabatic parameter modulations adopted can not reduce excitations and weaken the slowing down effect. Additionally, a feasible experimental scheme is also suggested to achieve the anticipated exponential super-Heisenberg scaling. Our findings strongly indicate that criticality-enhanced metrology can indeed significantly enhance measuring precision to a super-Heisenberg scaling when combining a triple point and beneficial parameter modulations in the adiabatic evolution, which will be conducive to the exploration of other super-Heisenberg scaling and their applications.
Quantum Physics
What problem does this paper attempt to address?
This paper attempts to solve the following two key problems: 1. **Does quantum criticality always improve measurement accuracy?** Through research, the author found that quantum criticality does not always enhance measurement accuracy. Specifically, under certain parameter modulation conditions, the quantum Fisher information (QFI) may maintain a finite value, which means that quantum criticality is unhelpful for quantum metrology in this case. 2. **During the adiabatic modulation process, if the slow - varying rate can be safely set to be not less than or close to the energy gap, can super - Heisenberg scaling (SHS) be achieved?** The paper shows that by combining triple - point criticality and appropriate adiabatic parameter modulation, exponential super - Heisenberg scaling can indeed be achieved. However, if the adiabatic path fails to effectively suppress excitation or accelerate the adiabatic process, it will degenerate into sub - Heisenberg scaling. --- ### Specific research content and solutions #### Research background Quantum metrology aims to improve measurement accuracy by using quantum resources such as entanglement and squeezed states. The classical measurement accuracy is limited by the quantum standard limit (QSL), and the Heisenberg limit (HL) can be reached through quantum correlations. However, super - Heisenberg scaling, which exceeds the Heisenberg limit, is usually difficult to achieve, especially in practical systems limited by the coherence time. #### Core findings The paper uses the anisotropic quantum Rabi model (aQRM) as the research object to explore quantum - critical - enhanced metrology near the triple point. The main conclusions are as follows: 1. **The relationship between the behavior of QFI and parameter modulation**: - Near the first - order or second - order phase - transition critical points, QFI usually diverges because the energy gap closes and the matrix elements are non - zero. - Near the triple point, whether QFI diverges depends on the specific relationship between \(g_1\) and \(g_2\). For example, when \(1-\frac{g_1}{g_c}=k\left(\frac{g_2}{g_c}\right)^\beta\): - If \(0 < \beta < \frac{1}{2}\), QFI tends to zero; - If \(\beta=\frac{1}{2}\), QFI has a finite value; - If \(\frac{1}{2}<\beta < 1\) or \(\beta = 1\), QFI diverges. 2. **The realization of super - Heisenberg scaling**: - By designing an appropriate adiabatic modulation protocol, the excitation part during the adiabatic evolution process can be suppressed, thereby accelerating the evolution and achieving exponential super - Heisenberg scaling. The specific formula is: \[ F_\omega\approx\frac{1}{8\omega^2}(k^2 - 1)^2e^{8\delta\omega\sqrt{1-\frac{1}{k^2}}T} \] This shows that, relative to the adiabatic evolution time \(T\), the measurement accuracy can significantly exceed the traditional Heisenberg limit. 3. **The case of sub - Heisenberg scaling**: - If adiabatic modulation fails to effectively suppress excitation (for example, \(\partial_{g_2}\gamma\) diverges), it will lead to sub - Heisenberg scaling: \[ F_\omega\approx\frac{1}{8}k^4\omega^2(4\delta k\omega T)^{2-\frac{1}{\beta}} \] where \(2-\frac{1}{\beta}<1\), indicating that the accuracy is lower than the Heisenberg limit. #### Experimental feasibility The paper proposes an experimental scheme based on trapped ions to verify the above theoretical predictions. Specifically: - Use \(^{43}\)