Modelling, Design Optimization and Prototype development of Knee Exoskeleton

Shashank Mani Gautam,Ekta Singla,Ashish Singla
2024-09-04
Abstract:This study focuses on enhancing the design of an existing knee exoskeleton by addressing limitations in the range of motion (ROM) during Sit-to-Stand (STS) motions. While current knee exoskeletons emphasize toughness and rehabilitation, their closed-loop mechanisms hinder optimal ROM, which is crucial for effective rehabilitation. This research aims to optimize the exoskeleton design to achieve the necessary ROM, improving its functionality in rehabilitation. This can be achieved by utilizing kinematic modeling and formulation, the existing design was represented in the non-linear and non-convex mathematical functions. Optimization techniques, considering constraints based on human leg measurements, were applied to determine the best dimensions for the exoskeleton. This resulted in a significant increase in ROM compared to existing models. A MATLAB program was developed to compare the ROM of the optimized exoskeleton with the original design. To validate the practicality of the optimized design, analysis was conducted using a mannequin with average human dimensions, followed by constructing a cardboard dummy model to confirm simulation results. The STS motion of an average human was captured using a camera and TRACKER software, and the motion was compared with that of the dummy model to identify any misalignments between the human and exoskeleton knee joints. Furthermore, a prototype of the knee joint exoskeleton is being developed to further investigate misalignments and improve the design. Future work includes the use of EMG sensors for more detailed analysis and better results.
Robotics,Optimization and Control
What problem does this paper attempt to address?
The problem this paper attempts to address is the limited Range of Motion (ROM) of existing knee exoskeletons during Sit-to-Stand (STS) movements. Although current knee exoskeletons perform well in terms of strength and rehabilitation, their closed-loop mechanism restricts the optimal range of motion, which is crucial for surgical rehabilitation. Therefore, this study aims to enhance the functionality and range of motion in rehabilitation by optimizing the exoskeleton design. Specifically, the paper addresses this issue through the following steps: 1. **Modeling and Formulation**: Using kinematic modeling and mathematical formulation methods, the existing design is represented as nonlinear and non-convex mathematical functions. 2. **Optimization Techniques**: Based on constraints from human leg measurement data, optimization techniques are applied to determine the optimal dimensions of the exoskeleton, thereby significantly increasing the range of motion. 3. **Validation and Analysis**: Analysis is conducted using a dummy with average human dimensions, and a cardboard model is constructed to confirm the simulation results. The STS movement of an average human is captured using cameras and TRACKER software, and compared with the model's movement to identify any misalignment between the human and exoskeleton knee joints. 4. **Prototype Development**: A prototype of the knee exoskeleton is developed to further investigate misalignment issues and improve the design. Through these steps, the paper successfully enhances the range of motion of the knee exoskeleton during STS movements, thereby improving its functionality and effectiveness in rehabilitation. Future work includes more detailed analysis using EMG sensors for better results.