Characterization of SiPM Performance in a Small Satellite in Low Earth Orbit using LabOSat-01

Lucas Finazzi,Federico Izraelevitch,Mariano Barella,Fernando Gomez Marlasca,Gabriel Sanca,Federico Golmar
DOI: https://doi.org/10.1016/j.nima.2024.169711
2024-08-23
Abstract:In this work, the performance of SensL MicroFC-60035 SiPM devices was studied during a 1460-day mission in Low Earth Orbit (LEO) using the LabOSat-01 characterization payload. Two of these platforms, carrying two SiPMs each, were integrated into the ÑuSat-7 satellite (COSPAR-ID: 2020-003B). Analysis revealed that these SiPMs experienced an increase in dark current over time due to damage from trapped and solar proton radiation. The total ionizing dose received by the payload and the SiPMs was measured using p-MOSFET dosimeters, with a resulting value of 5 Gy, or a 1 MeV neutron equivalent fluence of $\phi_n = 5 \cdot 10^9$ n/cm$^2$. The dark current was observed to increase up to 500 times. Parameters such as Gain and Photon Detection Efficiency remained unchanged throughout the mission. These findings align with previous performance reports involving different SiPMs irradiated with various particles and energies.
Instrumentation and Detectors
What problem does this paper attempt to address?
### Problems the paper attempts to solve This paper aims to study and characterize the performance changes of SensL MicroFC - 60035 silicon photomultiplier tubes (SiPMs) in low - earth orbit (LEO). Specifically, the paper focuses on the following issues: 1. **Impact of radiation damage**: Study the radiation damage to SiPMs in low - earth orbit, especially the impact from trapped protons and solar proton radiation. These radiations will cause an increase in the dark current of SiPMs, thus affecting their performance. 2. **Long - term performance assessment**: Through a 1460 - day mission, assess the long - term performance stability of SiPMs in the space environment. Particular attention is paid to whether key parameters of SiPMs such as gain and photon detection efficiency (PDE) remain unchanged. 3. **Radiation dose measurement**: Use p - MOSFET dosimeters to measure the total ionization dose (TID) received by the payload and SiPMs, and compare it with the 1 MeV neutron equivalent flux to verify the radiation damage estimation method. 4. **Temperature - dependence analysis**: Study the performance changes of SiPMs at different temperatures, especially the impact of temperature fluctuations on the SiPM dark current when the satellite enters the shadow area and the sunlight area. 5. **Recovery mechanism exploration**: It has been observed that in the later stage of the mission, as the satellite altitude decreases and the temperature rises, there is a slight recovery of the radiation damage of SiPMs. Explore whether this recovery is related to the annealing effect. ### Research background Silicon photomultiplier tubes (SiPMs), as an advanced solid - state optoelectronic device, exhibit superior performance in multiple fields, especially suitable for space applications. However, due to the existence of high - energy particle radiation in the space environment, SiPMs may suffer radiation damage, resulting in performance degradation. Therefore, understanding and evaluating the performance changes of SiPMs in low - earth orbit are crucial for the design and optimization of future space missions. ### Main findings - **Significant increase in dark current**: During the mission, the dark current of SiPMs increased by approximately 500 times, which was mainly caused by radiation damage. - **Stability of other performance parameters**: Although the dark current increased significantly, the gain and photon detection efficiency of SiPMs remained unchanged throughout the mission. - **Radiation dose measurement**: The total ionization dose measured by the p - MOSFET dosimeter was 5 Gy, and the corresponding 1 MeV neutron equivalent flux was \( \phi_n = 5\times 10^9 \, \text{n/cm}^2 \). - **Weakening of temperature - dependence**: The rate of increase in the dark current of the damaged SiPMs with temperature became slower, changing from doubling every 10 °C increase to doubling every 20 °C increase. - **Slight recovery phenomenon**: In the later stage of the mission, as the satellite altitude decreased and the temperature increased, the dark current of SiPMs had a slight recovery, which might be related to the annealing effect. ### Conclusion This study shows that although SiPMs in low - earth orbit have suffered significant radiation damage, resulting in a large increase in dark current, their key performance parameters such as gain and photon detection efficiency still remain stable. In addition, the research results verify the validity of the 1 MeV equivalent flux estimation and the NIEL scaling hypothesis, providing an important reference for the selection and design of SiPMs in future space missions.