Enhancing Diagnostic Reliability of Foundation Model with Uncertainty Estimation in OCT Images

Yuanyuan Peng,Aidi Lin,Meng Wang,Tian Lin,Ke Zou,Yinglin Cheng,Tingkun Shi,Xulong Liao,Lixia Feng,Zhen Liang,Xinjian Chen,Huazhu Fu,Haoyu Chen
2024-06-18
Abstract:Inability to express the confidence level and detect unseen classes has limited the clinical implementation of artificial intelligence in the real-world. We developed a foundation model with uncertainty estimation (FMUE) to detect 11 retinal conditions on optical coherence tomography (OCT). In the internal test set, FMUE achieved a higher F1 score of 96.76% than two state-of-the-art algorithms, RETFound and UIOS, and got further improvement with thresholding strategy to 98.44%. In the external test sets obtained from other OCT devices, FMUE achieved an accuracy of 88.75% and 92.73% before and after thresholding. Our model is superior to two ophthalmologists with a higher F1 score (95.17% vs. 61.93% &71.72%). Besides, our model correctly predicts high uncertainty scores for samples with ambiguous features, of non-target-category diseases, or with low-quality to prompt manual checks and prevent misdiagnosis. FMUE provides a trustworthy method for automatic retinal anomalies detection in the real-world clinical open set environment.
Image and Video Processing,Artificial Intelligence,Computer Vision and Pattern Recognition