A Precision Gyroscope from the Spin of Light

Michael A. Fedderke,Roni Harnik,David E. Kaplan,Sam Posen,Surjeet Rajendran,Francesco Serra,Vyacheslav P. Yakovlev
2024-06-24
Abstract:We describe a gyroscope that measures rotation based on the effects of the rotation on the polarization of light. Rotation induces a differential phase shift in the propagation of left and right circularly polarized light and this phase shift can be measured in suitably designed interferometric setups. The signal in this setup is independent of the frequency of light, unlike various sources of noise such as vibrations, which cause phase shifts that depend on the frequency. Such vibrations are the practical limit on the sensitivity of conventional Sagnac-style optical interferometers that are typically used as gyroscopes. In the proposed setup, one can potentially mitigate this source of noise by simultaneously using two (or more) sources of light that have different frequencies. The signal in this setup scales with the total storage time of the light. Due to its frequency independence, it is thus most optimal to measure the signal using superconducting RF systems where the high finesse of the available cavities enables considerably longer storage times than is possible in an optical setup.
Optics,Quantum Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to measure rotation through the polarization effect of light. Specifically, the author proposes a new gyroscope design that utilizes the influence of rotation on the propagation of left - and right - handed circularly polarized light to measure rotation. The core advantage of this method is that the phase difference it measures is independent of the frequency of light, which enables it to effectively reduce the noise caused by vibration. In contrast, the traditional Sagnac interferometer is susceptible to this type of noise when measuring rotation. ### Analysis of the Core Problems in the Paper 1. **Limitations of Traditional Methods**: - The traditional Sagnac interferometer measures rotation by detecting the change in path length of light in a closed path due to rotation. However, a major problem with this method is that any low - frequency vibration will cause a phase change similar to the rotation signal. These phase changes are also proportional to the frequency of light, making it difficult to distinguish between the rotation signal and vibration noise. 2. **Advantages of the New Method**: - The new method is based on the differential influence of rotation on the propagation of left - and right - handed circularly polarized light. Rotation will cause a relative phase change between these two polarized lights. This phase change is independent of the frequency of light and depends only on the rotation rate and the storage time of light in the cavity. - Since the phase change is independent of the frequency, it can be measured by using two light sources with different frequencies simultaneously, thereby separating the phase change caused by vibration and extracting the rotation signal more accurately. 3. **Experimental Setup**: - The author proposes an experimental setup that uses two Fabry - Pérot cavities to store left - and right - handed circularly polarized light. These two cavities are arranged along the rotation axis, and the phase difference between the two polarized lights is measured by interference. - To maximize the phase difference, high - finesse superconducting radio - frequency (RF) cavities can be used because these cavities can store light for a longer time, thereby increasing the measurement sensitivity. ### Explanation of Mathematical Formulas - **Phase Difference Formula**: \[ \Delta \Phi \sim \frac{4F}{\pi} \Omega L \] where: - \( \Delta \Phi \) is the phase difference between the two polarized lights. - \( F \) is the finesse of the cavity. - \( \Omega \) is the rotation rate. - \( L \) is the length of the cavity. - **Sensitivity Estimation**: \[ \Omega \sim 10^{-11} \text{Hz} \sqrt{\text{Hz}} \left( \frac{10^9}{F} \right) \left( \frac{1 \text{m}}{L} \right) \left( \frac{P_{\text{max}}}{1 \text{MW}} \right) \left( \frac{2\pi \times 10 \text{GHz}}{\omega} \right) \] where: - \( \Omega \) is the sensitivity of the rotation rate. - \( F \) is the finesse of the cavity. - \( L \) is the length of the cavity. - \( P_{\text{max}} \) is the circulating power. - \( \omega \) is the angular frequency of light. ### Conclusion This paper proposes a new method based on the light polarization effect for high - precision rotation measurement. By utilizing the differential influence of rotation on the propagation of left - and right - handed circularly polarized light, this method can effectively reduce the noise caused by vibration, thereby increasing the measurement sensitivity. This technology is expected to be widely used in commercial and scientific research fields, especially in applications that require high - precision rotation measurement.