Polarimetry of $γ$-Rays Converting to $e^+e^-$ Pairs with Silicon-Pixel-Based Telescopes

Denis Bernard
2024-06-27
Abstract:There are serious prospects that the next $\gamma$-ray space mission could use a telescope based on silicon pixel detectors. I characterize the potential of such active targets for polarimetry with gamma-ray conversions to pairs and find it excellent both in terms of selection efficiency and of effective polarization asymmetry.
Instrumentation and Methods for Astrophysics,High Energy Astrophysical Phenomena,Instrumentation and Detectors
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to improve the accuracy and efficiency of high - energy γ - ray polarization measurement, especially in the MeV energy range. Specifically, the author studied the polarization measurement performance of telescopes based on silicon - pixel - based detectors when γ - rays are converted into electron - positron pairs (e⁺e⁻ pairs). ### Main problems: 1. **Limitations of existing technologies**: Currently, there is no γ - ray polarimeter for space missions, resulting in the lack of polarization data of cosmic sources in the MeV energy range. 2. **Multiple - scattering effect**: Due to the multiple scattering of electrons and positrons in the detector, it is extremely difficult to measure the final - state azimuthal angle (azimuthal angle, φ), thus affecting the measurement of polarization asymmetry. 3. **Low sensitivity**: The sensitivity of existing detector designs (such as Fermi - LAT) is limited in the low - energy range, which restricts the ability to measure the polarization of low - energy γ - rays. ### Research objectives: - **Evaluate the potential of silicon - pixel detectors**: Through simulation and analysis, evaluate the selection efficiency and effective polarization asymmetry of silicon - pixel detectors in γ - ray polarization measurement. - **Optimize detector parameters**: Study the influence of different parameters (such as wafer thickness, pixel size, wafer spacing) on the polarization measurement performance to find the best configuration. - **Improve measurement accuracy**: Aim to achieve a measurement of the polarization fraction of the brightest MeV γ - ray sources with an accuracy of a few percent through improving the detector design. ### Key conclusions: - **Advantages of silicon - pixel detectors**: Compared with traditional strip detectors, silicon - pixel detectors show higher selection efficiency and better polarization asymmetry in polarization measurement. - **Parameter optimization**: Thinner wafers and larger wafer spacings help to improve polarization asymmetry and selection efficiency. - **Future prospects**: The research shows that using optimized silicon - pixel detectors can significantly improve the accuracy of polarization measurement of MeV γ - ray sources, providing new possibilities for future space missions. ### Formula summary: - **Dilution factor \(D\)**: \[ D=\exp\left(- 2\sigma_0^2\frac{x}{X_0}\right) \] where \(\sigma_0\approx24\text{ rad}\), \(x\) is the thickness of the scatterer, and \(X_0\) is the radiation length. - **Effective value of polarization asymmetry \(A\)**: \[ A = D\cdot A_{\text{QED}} \] where \(A_{\text{QED}}\) is the theoretical value in quantum electrodynamics. - **Measurement accuracy \(\sigma_P\)**: \[ \sigma_P=\sqrt{\frac{2P}{\sum_k A_k^2 N_k}} \] where \(A_k\) and \(N_k\) are the effective polarization asymmetry and the number of events in the \(k\) - th energy interval respectively. Through these studies, the author shows the great potential of silicon - pixel detectors in high - energy γ - ray polarization measurement and provides an important reference for future designs.