Guiding the Last Centimeter: Novel Anatomy-Aware Probe Servoing for Standardized Imaging Plane Navigation in Robotic Lung Ultrasound

Xihan Ma,Mingjie Zeng,Jeffrey C. Hill,Beatrice Hoffmann,Ziming Zhang,Haichong K. Zhang
2024-06-17
Abstract:Navigating the ultrasound (US) probe to the standardized imaging plane (SIP) for image acquisition is a critical but operator-dependent task in conventional freehand diagnostic US. Robotic US systems (RUSS) offer the potential to enhance imaging consistency by leveraging real-time US image feedback to optimize the probe pose, thereby reducing reliance on operator expertise. However, determining the proper approach to extracting generalizable features from the US images for probe pose adjustment remain challenging. In this work, we propose a SIP navigation framework for RUSS, exemplified in the context of robotic lung ultrasound (LUS). This framework facilitates automatic probe adjustment when in proximity to the SIP. This is achieved by explicitly extracting multiple anatomical features presented in real-time LUS images and performing non-patient-specific template matching to generate probe motion towards the SIP using image-based visual servoing (IBVS). This framework is further integrated with the active-sensing end-effector (A-SEE), a customized robot end-effector that leverages patient external body geometry to maintain optimal probe alignment with the contact surface, thus preserving US signal quality throughout the navigation. The proposed approach ensures procedural interpretability and inter-patient adaptability. Validation is conducted through anatomy-mimicking phantom and in-vivo evaluations involving five human subjects. The results show the framework's high navigation precision with the probe correctly located at the SIP for all cases, exhibiting positioning error of under 2 mm in translation and under 2 degree in rotation. These results demonstrate the navigation process's capability to accomondate anatomical variations among patients.
Robotics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to automatically navigate the ultrasound probe to the Standardized Imaging Plane (SIP) in Robotic Lung Ultrasound (LUS) to improve the consistency and accuracy of image acquisition. Specifically, the paper focuses on how to generate probe movement by real - time extraction of multiple anatomical features in ultrasound images and non - patient - specific template matching when approaching SIP, thereby achieving automatic probe adjustment. This process aims to reduce the dependence on the operator's experience and improve the consistency of imaging results among different patients. ### Main Challenges 1. **Difficulty in Interpreting Ultrasound Images**: Ultrasound images are planar images with limited information and are easily affected by noise and artifacts, making it difficult to automatically identify useful content. 2. **Variability among Patients**: The same anatomical structure in different patients may present different images, making SIP navigation difficult to generalize to different clinical cases. 3. **Alignment Problem between Probe and Contact Surface**: When the alignment between the probe and the tissue is poor, the quality of the echo signal will decline, affecting the robustness of navigation. ### Solutions The paper proposes a SIP navigation framework that combines artificial intelligence (AI) and Image - Based Visual Servoing (IBVS). The specific contributions are as follows: 1. **SIP Navigation Framework**: A real - time framework is introduced, which uses a convolutional neural network (CNN) to generate instance masks, identify multiple anatomical structures, and is further used for in - plane probe servo control. 2. **Anatomical Feature Map (AFM)**: A novel concept, AFM, is proposed to extract general visual features from the current ultrasound image for robust IBVS in - plane servo control. 3. **Active Sensing End - Effector (A - SEE)**: A customized robotic end - effector A - SEE is integrated, which ensures the best ultrasound image quality throughout the navigation process by continuously adjusting the probe direction. ### Experimental Verification This framework has been verified on simulated phantoms and multiple human subjects. The results show that the probe can be positioned at SIP with millimeter - level precision, with a translation error of less than 2 millimeters and a rotation error of less than 2 degrees. These results indicate that this navigation process can adapt to anatomical variations among different patients. ### Future Prospects Although the preliminary results demonstrate the effectiveness of this framework in guiding robotic LUS procedures, its performance in other soft - tissue examinations (such as liver and thyroid ultrasounds) still needs further verification. In the future, this framework can be applied to various ultrasound examinations by implementing specific anatomical feature detection modules.