Enhancing Membrane-Based Scanning Force Microscopy Through an Optical Cavity

Thomas Gisler,David Hälg,Vincent Dumont,Shobhna Misra,Letizia Catalini,Eric C. Langman,Albert Schliesser,Christian L. Degen,Alexander Eichler
2024-06-11
Abstract:The new generation of strained silicon nitride resonators harbors great promise for scanning force microscopy, especially when combined with the extensive toolbox of cavity optomechanics. However, accessing a mechanical resonator inside an optical cavity with a scanning tip is challenging. Here, we experimentally demonstrate a cavity-based scanning force microscope based on a silicon nitride membrane sensor. We overcome geometric constraints by making use of the extended nature of the mechanical resonator normal modes, which allows us to spatially separate the scanning and readout sites of the membrane. Our microscope is geared towards low-temperature applications in the zeptonewton regime, such as nanoscale nuclear spin detection and imaging.
Optics,Mesoscale and Nanoscale Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to improve the detection efficiency of mechanical resonators and reduce read - out noise in scanning force microscopy by using optical cavities. Specifically, the main challenge faced by the researchers is how to achieve high - sensitivity force detection under low - temperature conditions, especially in applications at the zeptonewton level, such as nuclear spin detection and imaging at the nanoscale. Traditional interferometry methods are limited by read - out noise at low temperatures, which hinders further improvement of their performance. For this reason, the paper proposes an optical - cavity - based scanning force microscope with a silicon nitride membrane sensor. By utilizing the extended - mode characteristics of the mechanical resonator, it realizes the spatial separation of the scanning site and the read - out site, thereby overcoming geometric constraints, reducing read - out noise, and improving the overall performance of the system. ### Specific problems solved by the paper: 1. **Reducing read - out noise**: By placing mechanical components in a high - finesse optical cavity, read - out noise can be significantly reduced, especially under broadband conditions. This enables the system to achieve a lower force - noise budget in a low - temperature environment, thereby increasing the sensitivity of force detection. 2. **Improving detection efficiency**: The use of an optical cavity not only reduces optical heating but also allows multiple mechanical modes to be cooled simultaneously, further improving detection efficiency. 3. **Spatial separation**: By utilizing the extended - mode characteristics of the mechanical resonator, the spatial separation of the scanning site and the read - out site is achieved, overcoming geometric constraints and enabling the scanning probe to approach the diaphragm without interfering with the optical read - out. 4. **Low - temperature applications**: This system is particularly suitable for high - sensitivity force detection under low - temperature conditions, such as nuclear spin detection and imaging at the nanoscale, which is of great significance in life - science and materials - science research. ### Technical details: - **Optical - cavity design**: A high - finesse optical cavity is used, which increases the number of laser circulations in the cavity, thereby increasing the signal strength and reducing read - out noise. - **Phase stabilization**: Through phase - stabilization techniques, laser - frequency noise is reduced, further reducing read - out noise. - **Mechanical resonator**: A high - stress silicon nitride membrane is used as a mechanical resonator. Its high Q - value and low mass make it an ideal force - detection sensor. - **Scanning mechanism**: An inverted atomic force microscope (AFM) geometry is adopted. The sample is placed on the diaphragm surface, and a non - rigid scanning probe approaches the diaphragm to monitor the amplitude and frequency changes of the diaphragm vibration. Through these technical means, the paper successfully demonstrates that at room temperature, the system can achieve a thermal - limit - force - noise sensitivity of 180 aN/Hz^1/2 and achieve this performance within a bandwidth of 80 Hz. This lays a solid foundation for future low - temperature applications, especially nuclear spin detection and imaging at the nanoscale.