High-performance in-vacuum optical system for quantum optics experiments in a Penning-trap

Joaquín Berrocal,Daniel Rodríguez
2024-06-11
Abstract:Accurate measurements with implications in many branches in Physics have been accessed using Penning traps and conventional techniques within a temperature regime where each eigenmotion of a charged particle is still a classical harmonic oscillator. Cooling the particle directly or indirectly with lasers allows reaching the quantum regime of each oscillator, controlling subtle effects in the precision frontier by detecting photons instead of electric current. In this paper, we present a new in-vacuum optical system designed to detecting 397-nm fluorescence photons from individual calcium ions and Coulomb crystals in a 7-T Penning trap. Based on the outcome of computer simulations, our design shows diffraction-limited performance. The system has been characterized using a single laser-cooled ion as a point-like source, reaching a final resolution of 3.69(3) $\mu$m and 2.75(3) $\mu$m for the trap's axial and radial directions, respectively, after correcting aberrations.
Quantum Physics,Instrumentation and Detectors
What problem does this paper attempt to address?
This paper focuses on the design and implementation of a high-performance optical system in a high-vacuum environment for Penning traps in quantum optics experiments. A Penning trap is a device used to trap and manipulate charged particles, and it has various applications in physics. Traditionally, precise measurements of physical phenomena are made by monitoring the currents generated by particles on electrodes. However, by laser cooling ions and detecting fluorescence photons, it is possible to access the quantum vibration state and control more subtle effects. The paper introduces a new optical system in a vacuum, designed to detect fluorescence photons emitted by a single calcium ion or Coulomb crystal under a 7 Tesla magnetic field at a wavelength of 397 nanometers. The system is based on computer simulations and demonstrates diffraction-limited performance. It achieves sub-micrometer resolution by calibrating with a laser-cooled ion as a point light source. The optical system includes a target lens based on a non-spherical lens and a series of lenses to avoid aberrations, ultimately achieving a magnification of 15 times, enough to separate the projections of two ions on the sensor by several pixels. The purpose of the experiment is to improve momentum-frequency spectroscopy in Penning traps by detecting photons instead of currents, especially in the quantum field. This can improve measurement accuracy, reduce system errors related to mass-to-charge ratio, and be applicable to a wider range of particle types. The performance of the system after installation in vacuum was evaluated by analyzing the images of individual ions and utilizing wavefront aberration recovery techniques. Through system optimization, such as introducing cylindrical mirrors to correct aberrations, resolutions of approximately 3.69 micrometers and 2.75 micrometers were achieved in the axial and radial directions, respectively. In summary, this paper addresses the design and implementation of a high-performance optical system in a vacuum to enhance quantum optical measurements in Penning trap experiments, particularly improving the detection accuracy of the momentum state of individual ions.