Complex hemodynamic responses to trans-vascular electrical stimulation of the renal nerve in anesthetized pigs

Filippo Agnesi,Lucia Carlucci,Gia Burjanadze,Fabio Bernini,Khatia Gabisonia,John W Osborn,Silvestro Micera,Fabio A. Recchia
2024-05-29
Abstract:The objective of this study was to characterize hemodynamic changes during trans-vascular stimulation of the renal nerve and their dependence on stimulation parameters. We employed a stimulation catheter inserted in the right renal artery under fluoroscopic guidance, in pigs. Systolic, diastolic and pulse blood pressure and heart rate were recorded during stimulations delivered at different intravascular sites along the renal artery or while varying stimulation parameters (amplitude, frequency, and pulse width). Blood pressure changes during stimulation displayed a pattern more complex than previously described in literature, with a series of negative and positive peaks over the first two minutes, followed by a steady state elevation during the remainder of the stimulation. Pulse pressure and heart rate only showed transient responses, then they returned to baseline values despite constant stimulation. The amplitude of the evoked hemodynamic response was roughly linearly correlated with stimulation amplitude, frequency, and pulse width.
Quantitative Methods
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to study the hemodynamic changes caused by renal nerve stimulation via blood vessels and their dependence on stimulation parameters. Specifically, the researchers conducted experiments in pigs using a stimulation catheter inserted into the right renal artery and recorded the changes in systolic blood pressure, diastolic blood pressure, pulse pressure and heart rate when the intravascular position was different or the stimulation parameters (such as amplitude, frequency and pulse width) were changed. The study found that the pattern of blood pressure changes during stimulation was more complex than that described in previous literature, with a series of negative and positive peaks occurring within the first two minutes, and then entering a state of stable elevation during the remaining stimulation time. In addition, the study also explored the effects of different stimulation parameters (such as intensity, frequency and pulse width) on the hemodynamic response, and found that there was a roughly linear relationship between these responses and the stimulation parameters. In short, this study aims to gain a deeper understanding of the hemodynamic response characteristics and the underlying physiological mechanisms during renal nerve electro - stimulation via blood vessels, which may provide valuable references for future clinical renal artery neuromodulation therapy.