Enhancing grid frequency regulation in low inertia modern multi‐area power systems using cascaded non‐integer control approaches with BESS‐based virtual inertia
Tushar Kanti Roy,Amanullah Maung Than Oo
DOI: https://doi.org/10.1049/rpg2.13169
IF: 3.034
2024-12-02
IET Renewable Power Generation
Abstract:This study addresses the challenge of heightened frequency fluctuations and instability in modern power systems due to reduced system inertia caused by the integration of renewable energy sources. A proposed solution involves a virtual inertia and damping controller utilizing battery energy storage, along with a cascaded controller for load frequency control. Optimization of controller parameters using a whale optimization algorithm enhances system stability during high renewable energy penetration. Simulation results validate the efficacy of the proposed controllers, showcasing significant performance improvements compared to existing methods, particularly in managing contingencies within low‐inertia power systems. In modern power systems, the integration of inverter‐based renewable energy sources has significantly reduced system inertia, leading to heightened frequency fluctuations and potential instability within multi‐area interconnected microgrids. To counter this, a virtual inertia and damping controller utilizing battery energy storage, leveraging the virtual synchronous generator concept is proposed in this paper. This controller supplements inertia by modulating active power flow, thus stabilizing frequency during high renewable energy source penetration periods. Additionally, to enhance load frequency control, a cascaded controller combining adaptive neuro‐fuzzy inference system‐assisted fractional‐order PID with a nonlinear FOPI controller is introduced. It should be noted that improper controller parameters can worsen frequency deviations and system stability. Hence, a whale optimization algorithm optimizes control parameters using the integral time absolute error based objective function. Simulation studies on a modified IEEE 10‐generator 39‐bus power system, considering various disturbances like stochastic load‐generation, nonlinear generation behaviours, and time delay, validate the effectiveness of the proposed controller. Comparative analysis demonstrates the superior resilience of the cascaded control approach in managing contingencies within low‐inertia power systems, with a remarkable performance improvement of 87.9811% compared to existing control methods.
energy & fuels,engineering, electrical & electronic,green & sustainable science & technology