Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data

Huidong Xie,Weijie Gan,Bo Zhou,Ming-Kai Chen,Michal Kulon,Annemarie Boustani,Benjamin A. Spencer,Reimund Bayerlein,Wei Ji,Xiongchao Chen,Qiong Liu,Xueqi Guo,Menghua Xia,Yinchi Zhou,Hui Liu,Liang Guo,Hongyu An,Ulugbek S. Kamilov,Hanzhong Wang,Biao Li,Axel Rominger,Kuangyu Shi,Ge Wang,Ramsey D. Badawi,Chi Liu
2024-09-05
Abstract:Reducing scan times, radiation dose, and enhancing image quality, especially for lower-performance scanners, are critical in low-count/low-dose PET imaging. Deep learning (DL) techniques have been investigated for PET image denoising. However, existing models have often resulted in compromised image quality when achieving low-dose PET and have limited generalizability to different image noise-levels, acquisition protocols, and patient populations. Recently, diffusion models have emerged as the new state-of-the-art generative model to generate high-quality samples and have demonstrated strong potential for medical imaging tasks. However, for low-dose PET imaging, existing diffusion models failed to generate consistent 3D reconstructions, unable to generalize across varying noise-levels, often produced visually-appealing but distorted image details, and produced images with biased tracer uptake. Here, we develop DDPET-3D, a dose-aware diffusion model for 3D low-dose PET imaging to address these challenges. Collected from 4 medical centers globally with different scanners and clinical protocols, we extensively evaluated the proposed model using a total of 9,783 18F-FDG studies (1,596 patients) with low-dose/low-count levels ranging from 1% to 50%. With a cross-center, cross-scanner validation, the proposed DDPET-3D demonstrated its potential to generalize to different low-dose levels, different scanners, and different clinical protocols. As confirmed with reader studies performed by nuclear medicine physicians, experienced readers judged the images to be similar to or superior to the full-dose images and previous DL baselines based on qualitative visual impression. The presented results show the potential of achieving low-dose PET while maintaining image quality. Lastly, a group of real low-dose scans was also included for evaluation to demonstrate the clinical potential of DDPET-3D.
Image and Video Processing
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to improve image quality in low - dose positron emission tomography (PET) imaging while reducing scanning time and radiation dose, especially for scanners with lower performance. Although existing deep - learning techniques have been used for PET image denoising, they often lead to a decline in image quality when implementing low - count / low - dose PET, and have limited generalization ability across different noise levels, acquisition protocols and patient populations. In addition, existing diffusion models have difficulties in generating consistent 3D reconstructions, are unable to generalize across different noise levels, often produce visually appealing but distorted image details, and the generated images have biased tracer uptake. To this end, the authors developed DDPET - 3D, a dose - aware diffusion model specifically for 3D low - dose PET imaging, aiming to address the above challenges. This model has been extensively validated using a multi - center dataset, demonstrating its generalization ability at different low - dose levels, with different scanners and under different clinical protocols. Reader studies by nuclear medicine physicians show that experienced readers consider the images generated by this model to be similar to or better than full - dose images, and superior to previous deep - learning - based methods. Moreover, this study also included a set of real - low - dose scan data to demonstrate the clinical potential of DDPET - 3D. In summary, the main objective of this paper is to achieve low - dose PET imaging by developing a new diffusion model while maintaining image quality and clinical performance, thereby reducing radiation exposure, improving patient comfort, and enhancing image quality.