Improving hybrid image and structure-based deformable image registration for large internal deformations
Andrea Lorenzo Polo,Michael Nix,Christopher Thompson,Christopher John O'Hara,Jonathan Entwisle,Louis Murray,Ane L Appelt,Ola Weistrand,Stina Svensson
DOI: https://doi.org/10.1088/1361-6560/ad3723
IF: 3.5
2024-03-24
Physics in Medicine and Biology
Abstract:Deformable image registration (DIR) is a widely used technique in radiotherapy. Complex deformations, resulting from large anatomical changes, are a regular challenge. DIR algorithms generally seek a balance between capturing large deformations and preserving a smooth deformation vector field (DVF). We propose a novel structure-based term that can enhance the registration efficacy while ensuring a smooth DVF.
The proposed novel similarity metric for controlling structures was introduced as a new term into a commercially available algorithm. Its performance was compared to the original algorithm using a dataset of 46 patients who received pelvic re-irradiation (reRT), many of which exhibit complex deformations.
The mean dice similarity coefficient (DSC) under the improved algorithm was 0.95, 0.94, 0.77, and 0.90 for bladder, rectum, colon, and bone respectively, compared to 0.69, 0.89, 0.62, and 0.88 for the original algorithm. The improvement was more pronounced for complex deformations.
With this work, we have demonstrated that the proposed term is able to improve registration accuracy for complex cases while maintaining realistic deformations.
engineering, biomedical,radiology, nuclear medicine & medical imaging