Fluorescent Graphene Quantum Dots-Enhanced Machine Learning for Accurate Detection and Quantification of Hg2+ and Fe3+ in Real Water Samples

Mauricio Llaver,Santiago Daniel Barrionuevo,Jorge Martín Nuñez,Agostina Chapana,Rodolfo G. Wuilloud,Myriam Haydee Aguirre,Francisco Javier Ibañez
DOI: https://doi.org/10.1039/d3en00702b
2024-05-10
Abstract:Selective, accurate, fast, and with minimal usage of instrumentation has become paramount nowadays in areas of environmental monitoring. Here, we chemically modified fluorescent graphene quantum dots (GQDs) and trained a Machine Learning (ML) algorithm for the selective quantification of Hg2+ and Fe3+ ions present within real water samples. The probe is obtained by an electrosynthesis of CVD graphene in the presence of urea, followed by the functionalization with 1-nitroso-2-naphthol (NN). The functionalization with NN moieties dramatically improve selectivity and sensitivity toward Hg2+ and Fe3+, as demonstrated by LODs as low as 0.001 mg L-1 and 0.003 mg L-1; respectively. Time-dependent density-functional theory (TD-DFT) reveals that the NN molecules within the GQDs are responsible of the florescence emission of the probe. The emission spectra profiles exhibited distinct characteristics between Hg2+ and Fe3+ enabling the ML model to precisely quantify and differentiate between both analytes present in natural and drinking waters. The ML results were further validated by measurements via cold vapor-atomic fluorescence spectroscopy and UV-vis spectroscopy. The efficiency of the ML model eliminates the necessity of extensive training values and validations, making it a reliable tool for precisely quantifying the presence of Fe and Hg ions in real water samples.
Mesoscale and Nanoscale Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a selective, accurate and rapid method for detecting Hg²⁺ and Fe³⁺ ions in real water samples while minimizing the use of instruments. Specifically, the researchers achieved selective and highly sensitive detection of these two ions by chemically modifying fluorescent graphene quantum dots (GQDs) and combining with machine - learning (ML) algorithms. ### Research Background and Problem Description 1. **Requirements for Environmental Monitoring**: - In the field of environmental monitoring, selective, accurate and rapid detection methods are crucial. Especially for the detection of heavy metal ions such as Hg²⁺ and Fe³⁺ in water, these ions have high solubility and volatility and are extremely harmful to humans, animals and the environment. 2. **Limitations of Existing Technologies**: - Traditional detection methods usually require complex instruments and cumbersome operations, with high costs and low efficiency. Therefore, it is particularly important to develop a simple, low - cost and efficient detection method. 3. **Advantages and Challenges of GQDs**: - Graphene quantum dots (GQDs) have broad application prospects in metal ion detection due to their excellent optical properties. However, their selectivity and sensitivity still face challenges, especially in the presence of multiple other ions in real water samples. ### Solutions 1. **Chemically Modifying GQDs**: - The researchers prepared nitrogen - doped GQDs by electrosynthesis and further functionalized them with 1 - nitroso - 2 - naphthol (NN). This modification significantly improved the selectivity and sensitivity of GQDs to Hg²⁺ and Fe³⁺, with detection limits reaching 0.001 mg/L and 0.003 mg/L respectively. 2. **Combining with Machine Learning**: - The researchers trained a machine - learning model based on 191 excitation - emission matrices (EEMs) data to accurately quantify and distinguish Hg²⁺ and Fe³⁺ in water samples. Verified by time - dependent density functional theory (TD - DFT) simulations, the introduction of NN molecules into GQDs enhanced the fluorescence emission characteristics, enabling the ML model to effectively identify these two ions. 3. **Verification and Application**: - This method was tested in river, reservoir and tap water samples and verified by cold - vapor atomic fluorescence spectrometry (CV - AFS) and ultraviolet - visible spectrometry (UV - vis). The results showed that this method is not only efficient and accurate, but also greatly reduces the time for experimental operations and instrument processing. ### Conclusion This study shows how to significantly improve the detection sensitivity and selectivity of harmful ions by chemically modifying GQDs and combining with efficient machine - learning algorithms, thus providing a new, user - friendly spectroscopic technology tool for environmental monitoring.