High-precision chemical quantum sensing in flowing monodisperse microdroplets

Adrisha Sarkar,Zachary Jones,Madhur Parashar,Emanuel Druga,Amala Akkiraju,Sophie Conti,Pranav Krishnamoorthi,Srisai Nachuri,Parker Aman,Mohammad Hashemi,Nicholas Nunn,Marco Torelli,Benjamin Gilbert,Kevin R. Wilson,Olga Shenderova,Deepti Tanjore,Ashok Ajoy
2024-04-30
Abstract:We report on a novel flow-based method for high-precision chemical detection that integrates quantum sensing with droplet microfluidics. We deploy nanodiamond particles hosting fluorescent nitrogen vacancy defects as quantum sensors in flowing, monodisperse, picoliter-volume microdroplets containing analyte molecules. ND motion within these microcompartments facilitates close sensor-analyte interaction and mitigates particle heterogeneity. Microdroplet flow rates are rapid (upto 4cm/s) and with minimal drift. Pairing this controlled flow with microwave control of NV electronic spins, we introduce a new noise-suppressed mode of Optically Detected Magnetic Resonance that is sensitive to chemical analytes while resilient against experimental variations, achieving detection of analyte-induced signals at an unprecedented level of a few hundredths of a percent of the ND fluorescence. We demonstrate its application to detecting paramagnetic ions in droplets with simultaneously low limit-of-detection and low analyte volumes, in a manner significantly better than existing technologies. This is combined with exceptional measurement stability over >103s and across hundreds of thousands of droplets, while utilizing minimal sensor volumes and incurring low ND costs (<$0.70 for an hour of operation). Additionally, we demonstrate using these droplets as micro-confinement chambers by co-encapsulating ND quantum sensors with analytes, including single cells. This versatility suggests wide-ranging applications, like single-cell metabolomics and real-time intracellular measurements in bioreactors. Our work paves the way for portable, high-sensitivity, amplification-free, chemical assays with high throughput; introduces a new chemical imaging tool for probing chemical reactions in microenvironments; and establishes the foundation for developing movable, arrayed quantum sensors through droplet microfluidics.
Quantum Physics,Mesoscale and Nanoscale Physics,Applied Physics,Quantitative Methods
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to improve the accuracy and efficiency of chemical detection, especially to achieve high - sensitivity and high - throughput quantum sensing in microfluidic systems. Specifically, the researchers proposed a new method based on the combination of nanodiamond (ND) and droplet microfluidic technology for high - precision chemical detection in rapidly flowing monodisperse picoliter - level droplets. ### Research Background and Problems Traditional quantum sensing methods usually rely on single - crystal diamonds containing shallow nitrogen - vacancy (NV) centers, and this method has the following challenges: 1. **High Cost**: Single - crystal diamonds are expensive. 2. **Size Limitation**: The size of single - crystal diamonds is small (millimeter - level), making it difficult to integrate into microfluidic systems. 3. **Low Sensor Utilization**: Only part of the diamond crystal is used for sensing, and a complex microfluidic structure needs to be directly integrated onto the diamond. 4. **Large Statistical Error in Multi - Particle Analysis**: Due to the heterogeneity in particle size, shape, and NV - center coherence time of nanodiamonds (ND), there is a large statistical error in multi - particle analysis. ### Solutions To solve the above problems, the researchers proposed a new method, that is, embedding nanodiamond particles into rapidly flowing monodisperse picoliter - level droplets. This method has the following advantages: 1. **Overcoming the Heterogeneity Problem**: The rapid movement of ND particles within the droplet effectively averages out their heterogeneity, ensuring close interaction with the analyte. 2. **Stable and Controllable Flow**: Using the stable and controllable flow provided by droplet microfluidic technology, a new quantum sensing method without background noise has been developed, achieving high - throughput detection. 3. **High Measurement Stability**: Dynamically flowing droplets are highly resistant to experimental changes and temperature fluctuations, and can maintain measurement stability for more than 10^3 seconds and across about 10^5 droplets. 4. **Low Cost**: The required ND sensor has a very small volume, and the analysis cost per hour is only about $0.63. ### Application Prospects By combining quantum sensing with droplet microfluidic technology, this research provides a new platform technology for portable, high - sensitivity, and amplification - free chemical analysis. In addition, this technology is also suitable for applications such as real - time monitoring of single - cell metabolomics in bioreactors and micro - environmental imaging of probe chemical reactions. In conclusion, this paper aims to achieve high - precision, high - throughput, and low - cost chemical detection through innovative microfluidic and quantum sensing technologies, solving several key problems existing in the current technologies.