Safety, feasibility, and acceptability of a novel device to monitor ischaemic stroke patients

Samuel J van Bohemen,Jeffrey M Rogers,Aleksandra Alavanja,Andrew Evans,Noel Young,Philip C Boughton,Joaquin Valderrama,Andre Z Kyme
2024-03-26
Abstract:This study assessed the safety, feasibility, and acceptability of a novel device to monitor ischaemic stroke patients. The device captured electroencephalography (EEG) and electrocardiography (ECG) data to compute an ECG-based metric termed the Electrocardiography Brain Perfusion index (EBPi), which may function as a proxy for cerebral blood flow (CBF). Seventeen ischaemic stroke patients wore the device for nine hours and reported feedback at 1, 3, 6 and 9 hours regarding user experience, comfort, and satisfaction (acceptability). Safety was assessed as the number of adverse events reported. Feasibility was assessed as the percentage of uninterrupted EEG/ECG data recorded (data capture efficiency). No adverse events were reported, only minor incidences of discomfort. Overall device comfort (92.5% +/- 10.3%) and data capture efficiency (95.8% +/- 6.8%) were very high with relatively low variance. The device did not restrict participants from receiving clinical care and rarely (n=6) restricted participants from undertaking routine tasks. This study provides a promising evidence base for the deployment of the device in a clinical setting. If clinically validated, EBPi may be able to detect CBF changes to monitor early neurological deterioration and treatment outcomes, thus filling an important gap in current monitoring options.
Medical Physics
What problem does this paper attempt to address?
### Problems the Paper Aims to Solve This paper aims to evaluate the safety, feasibility, and acceptability of a novel device for monitoring patients with ischemic stroke. Specifically, the device calculates an ECG-based index—ECG Brain Perfusion Index (EBPi)—by recording electroencephalogram (EEG) and electrocardiogram (ECG) data, which can serve as a surrogate marker for cerebral blood flow (CBF). #### Main Objectives: - **Safety**: Assess whether the device causes any adverse events. - **Feasibility**: Evaluate whether the device can continuously record EEG/ECG data. - **Acceptability**: Assess user experience, comfort, and satisfaction with the device. The study involved 17 ischemic stroke patients who wore the device for 9 hours in the hospital and provided feedback at 1 hour, 3 hours, 6 hours, and 9 hours. #### Background Information: - Globally, stroke is the second leading cause of death and the third leading cause of disability, affecting approximately 12 million people annually. - Currently, stroke diagnosis primarily relies on computed tomography (CT) imaging, which can only provide a "snapshot" at the time of diagnosis and cannot enable continuous monitoring. - Within 72 hours post-stroke, patients may experience early neurological deterioration (END), requiring early detection and intervention to prevent severe complications. #### Study Design: - A portable device was designed to wirelessly record EEG and ECG data and calculate EBPi. - A single-center observational study was conducted at Westmead Hospital in Sydney, recruiting 17 ischemic stroke patients for the experiment. - The safety, feasibility, and acceptability of the device were assessed through questionnaires. #### Summary of Results: - No adverse events or near-adverse events were reported. - Data capture efficiency was very high (average 95.8% ± 6.8%), indicating that the device successfully captured most of the EEG/ECG data. - Users rated the overall comfort of the device very high (average 92.5% ± 10.3%), indicating good acceptance of the device. - The device minimally restricted patients' daily activities (6 instances in total).