Versatile Capillary Cells for Handling Concentrated Samples in Analytical Ultracentrifugation

Quy Ong,Xufeng Xu,Francesco Stellacci
DOI: https://doi.org/10.1021/acs.analchem.3c05006
2024-03-15
Abstract:In concentrated macromolecular dispersions, far-from-ideal intermolecular interactions determine the dispersion behaviors including phase transition, crystallization, and liquid-liquid phase separation. Here, we present a novel versatile capillary-cell design for analytical ultracentrifugation-sedimentation equilibrium (AUC-SE), ideal for studying samples at high concentrations. Current setups for such studies are difficult and unreliable to handle, leading to a low experimental success rate. The design presented here is easy to use, robust, and reusable for samples in both aqueous and organic solvents while requiring no special tools or chemical modification of AUC cells. The key and unique feature is the fabrication of liquid reservoirs directly on the bottom window of AUC cells, which can be easily realized by laser ablation or mechanical drilling. The channel length and optical path length are therefore tunable. The success rate for assembling this new cell is close to 100%. We demonstrate the practicality of this cell by studying: 1) the equation of state and second virial coefficients of concentrated gold nanoparticle dispersions in water and bovine serum albumin (BSA) as well as lysozyme solution in aqueous buffers, 2) the gelation phase transition of DNA and BSA solutions, and 3) liquid-liquid phase separation of concentrated BSA/polyethylene glycol (PEG) droplets.
Soft Condensed Matter,Chemical Physics
What problem does this paper attempt to address?
The paper aims to address the challenges in handling high-concentration samples in the analysis of analytical ultracentrifugation sedimentation equilibrium (AUC-SE). Specifically, the current methods for studying high-concentration samples have the following issues: 1. **Operational Difficulty**: Existing AUC-SE devices are difficult to assemble and have low reliability, leading to a low success rate of experiments. 2. **Volume Limitation**: Only small volumes of liquid samples can be processed. 3. **Chemical Modification Requirement**: Special chemical modifications are needed for the samples or equipment. 4. **Solvent Applicability**: Not suitable for organic solvents and volatile solutions. The paper proposes a novel capillary cell design that can handle high-concentration samples easily and reliably, addressing the above issues. This design is particularly suitable for samples in aqueous and organic solvents and does not require any special tools or chemical modifications. With this method, researchers can more effectively study the behavior of high-concentration dispersed systems, including phenomena such as phase transitions and liquid-liquid phase separation.