A Dual-domain Regularization Method for Ring Artifact Removal of X-ray CT

Hongyang Zhu,Xin Lu,Yanwei Qin,Xinran Yu,Tianjiao Sun,Yunsong Zhao
2024-03-15
Abstract:Ring artifacts in computed tomography images, arising from the undesirable responses of detector units, significantly degrade image quality and diagnostic reliability. To address this challenge, we propose a dual-domain regularization model to effectively remove ring artifacts, while maintaining the integrity of the original CT image. The proposed model corrects the vertical stripe artifacts on the sinogram by innovatively updating the response inconsistency compensation coefficients of detector units, which is achieved by employing the group sparse constraint and the projection-view direction sparse constraint on the stripe artifacts. Simultaneously, we apply the sparse constraint on the reconstructed image to further rectified ring artifacts in the image domain. The key advantage of the proposed method lies in considering the relationship between the response inconsistency compensation coefficients of the detector units and the projection views, which enables a more accurate correction of the response of the detector units. An alternating minimization method is designed to solve the model. Comparative experiments on real photon counting detector data demonstrate that the proposed method not only surpasses existing methods in removing ring artifacts but also excels in preserving structural details and image fidelity.
Image and Video Processing,Computer Vision and Pattern Recognition
What problem does this paper attempt to address?
The paper primarily addresses the issue of ring artifacts in X-ray Computed Tomography (CT) images and proposes a novel solution. Ring artifacts are caused by inconsistencies in the detector unit response, which can lead to a decline in image quality and affect diagnostic accuracy. The proposed solution is a dual-domain regularization method that effectively removes ring artifacts while preserving the integrity of the original CT images. Specifically, this method innovatively updates the compensation coefficients for detector unit response inconsistencies to correct vertical stripe artifacts on the sinogram. This approach utilizes group sparse constraint and projection-view direction sparse constraint to handle stripe artifacts and applies sparse constraints in the image domain to further correct ring artifacts. The key advantage of this method lies in its consideration of the relationship between the compensation coefficients for detector unit response inconsistencies and the projection angles, making the correction of detector unit responses more precise. To solve the proposed model, the researchers designed an alternating minimization method. Experimental results show that compared to existing ring artifact removal methods, this method not only more effectively removes ring artifacts but also better preserves structural details and image fidelity. In summary, this paper aims to address the issue of ring artifacts in CT images caused by detector response inconsistencies by proposing a new dual-domain regularization method that achieves effective ring artifact removal.