Towards Precision Cardiovascular Analysis in Zebrafish: The ZACAF Paradigm

Amir Mohammad Naderi,Jennifer G. Casey,Mao-Hsiang Huang,Rachelle Victorio,David Y. Chiang,Calum MacRae,Hung Cao,Vandana A. Gupta
2024-02-15
Abstract:Quantifying cardiovascular parameters like ejection fraction in zebrafish as a host of biological investigations has been extensively studied. Since current manual monitoring techniques are time-consuming and fallible, several image processing frameworks have been proposed to automate the process. Most of these works rely on supervised deep-learning architectures. However, supervised methods tend to be overfitted on their training dataset. This means that applying the same framework to new data with different imaging setups and mutant types can severely decrease performance. We have developed a Zebrafish Automatic Cardiovascular Assessment Framework (ZACAF) to quantify the cardiac function in zebrafish. In this work, we further applied data augmentation, Transfer Learning (TL), and Test Time Augmentation (TTA) to ZACAF to improve the performance for the quantification of cardiovascular function quantification in zebrafish. This strategy can be integrated with the available frameworks to aid other researchers. We demonstrate that using TL, even with a constrained dataset, the model can be refined to accommodate a novel microscope setup, encompassing diverse mutant types and accommodating various video recording protocols. Additionally, as users engage in successive rounds of TL, the model is anticipated to undergo substantial enhancements in both generalizability and accuracy. Finally, we applied this approach to assess the cardiovascular function in nrap mutant zebrafish, a model of cardiomyopathy.
Image and Video Processing,Computer Vision and Pattern Recognition
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to automatically quantify cardiovascular parameters in zebrafish, especially ejection fraction (EF) and fractional shortening (FS), in order to improve research efficiency and accuracy. Specifically, the paper addresses the following issues: 1. **Limitations of Manual Monitoring Techniques**: Current manual monitoring techniques are time - consuming and error - prone, especially when dealing with large amounts of data. This restricts researchers from conducting efficient and accurate research on zebrafish cardiovascular function. 2. **Insufficient Generalization Ability of Existing Automated Methods**: Existing image - processing frameworks based on supervised learning perform poorly when dealing with new data, especially when using different imaging devices or data of different mutation types. This leads to a decline in the performance of the model in practical applications. 3. **Evaluation of Specific Mutation Types**: The paper pays special attention to the evaluation of cardiovascular function in *nrap* - mutant zebrafish, which is a gene mutation related to cardiomyopathy. Researchers hope to evaluate the impact of this mutation on zebrafish cardiovascular function through an improved automated method. To address these problems, researchers have developed and optimized a framework named ZACAF (Zebrafish Automatic Cardiovascular Assessment Framework). By introducing techniques such as data augmentation, transfer learning (TL), and test - time augmentation (TTA), the generalization ability and accuracy of the model have been improved. The application of these techniques enables ZACAF to better adapt to new datasets and different experimental conditions, thus providing a more reliable and efficient tool for zebrafish cardiovascular research.