CRANE: A Redundant, Multi-Degree-of-Freedom Computed Tomography Robot for Heightened Needle Dexterity within a Medical Imaging Bore

Dimitrious Schreiber,Zhaowei Yu,Taylor Henderson,Derek Chen,Alexander Norbasha,Michael C. Yip
2024-02-05
Abstract:Computed Tomography (CT) image guidance enables accurate and safe minimally invasive treatment of diseases, including cancer and chronic pain, with needle-like tools via a percutaneous approach. The physician incrementally inserts and adjusts the needle with intermediate images due to the accuracy limitation of free-hand adjustment and patient physiological motion. Scanning frequency is limited to minimize ionizing radiation exposure for the patient and physician. Robots can provide high positional accuracy and compensate for physiological motion with fewer scans. To accomplish this, the robots must operate within the confined imaging bore while retaining sufficient dexterity to insert and manipulate the needle. This paper presents CRANE: CT Robotic Arm and Needle Emplacer, a CT-compatible robot with a design focused on system dexterity that enables physicians to manipulate and insert needles within the scanner bore as naturally as they would be able to by hand. We define abstract and measurable clinically motivated metrics for in-bore dexterity applicable to general-purpose intra-bore image-guided needle placement robots, develop an automatic robot planning and control method for intra-bore needle manipulation and device setup, and demonstrate the redundant linkage design provides dexterity across various human morphology and meets the clinical requirements for target accuracy during an in-situ evaluation.
Robotics
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to improve the accuracy and safety of needle insertion in CT - guided minimally invasive surgeries while reducing the radiation exposure of patients and doctors. Specifically, the paper proposes the CRANE system, which is a high - precision, multi - degree - of - freedom robotic system designed to operate within the narrow space of a CT scanner. CRANE aims to overcome the limitations of existing robotic platforms in terms of automatic device setup, control, and needle insertion, which lead to performance compromises, increased changes in clinical workflows, loss of original capabilities, or reduced safety in some cases. Through its unique mechanical design and planning approach, CRANE can automatically set up the system, be compatible with commercially available biopsy and ablation probes, and insert needles into targets with only high - level control and minimal interaction, thus being suitable for patients of different body types. In addition, the design of CRANE also takes into account the system's redundancy and low profile to achieve minimal internal space occupation, sufficient flexibility, a large range of motion, passive driving ability, and the accuracy required clinically. The key contributions of the paper include: 1. **Robot Design**: A robot design with a low - profile, redundant serial link is proposed, which utilizes externally - driven and internally - cable - driven joints as well as redundant sensing to achieve minimal internal space occupation, sufficient flexibility for needle insertion, a large range of motion, passive driving ability, and the accuracy required clinically. 2. **Planning and Control Framework**: A unified framework is developed to control the redundant robot in combination with the task priorities specified by doctors to achieve automatic device setup operations. This framework is used for control synthesis in simulation design evaluation and in - situ experiments. 3. **Comprehensive Robot Flexibility Assessment**: A representative method for assessing the internal robot operation flexibility is developed, including clinical and synthetic cases. This method helps to improve the robot design to maximize the possible needle insertion trajectories within the patient, improve safety and ease of use, and expand the range of procedures that can be performed on a single platform. 4. **Grasping Mechanism**: A new type of clamping - type needle clamp using shape - memory - alloy (SMA) actuators is proposed, which enables deep - needle insertion through electromechanical clamping while maintaining a short overall length of the needle - insertion mechanism. This mechanism allows for the selection of an active remote - driving or doctor - involved control mode, in which the system only provides insertion - pose control without active insertion. Through these innovations, CRANE aims to address the challenges faced by existing technologies in CT - guided minimally invasive surgeries and improve the safety and efficiency of surgeries.