Adaptive FRIT-based Recursive Robust Controller Design Using Forgetting Factors

Satoshi Tsuruhara,Kazuhisa Ito
2024-05-01
Abstract:Adaptive FRIT (A-FRIT) with exponential forgetting (EF) has been proposed for time-varying systems to improve the data dependence of FRIT, which is a direct data-driven tuning method. However, the EF-based method is not a reliable controller because it can cause significant degradation of the control performance and instability unless the persistent excitation (PE) condition is satisfied. To solve this problem, we propose a new A-FRIT method based on directional forgetting (DF) and exponential resetting that can forget old data without instability regardless of the PE condition. To confirm the effectiveness of the proposed method, we applied it to artificial muscle control with strong asymmetric hysteresis characteristics and evaluated its robust performance against load changes during the experiment. The experimental results show that the proposed method based on DF achieves high control performance and is robust against changes in the characteristics and/or target trajectory. The proposed method is also practical because it does not require system identification, model structure, or prior experimentation.
Systems and Control
What problem does this paper attempt to address?
The paper attempts to address the reliability issues encountered in controller design using the Adaptive FRIT (A-FRIT) method in time-varying systems. Specifically, the traditional A-FRIT method, when introducing the Exponential Forgetting (EF) factor, can lead to significant degradation in control performance or even instability if the Persistent Excitation (PE) condition is not met. To solve this problem, the paper proposes a new A-FRIT method based on Directional Forgetting (DF) and Exponential Resetting (ER), which can achieve efficient forgetting without considering the PE condition, while ensuring system stability and robustness. The paper validates the effectiveness of the proposed method through experiments, applying it to a water-driven artificial muscle control system with strong asymmetric hysteresis characteristics, and testing it under different working conditions and load variations. The experimental results show that, compared to traditional methods, the new method exhibits higher robustness under various target trajectories, initial controller parameters, and load variation conditions. Additionally, the method allows designers to adjust the forgetting factor value more flexibly without causing system instability.