Abstract:We report the results of radioactivity assays and heat leak calculations for a range of common cryogenic materials, considered for use in the QUEST-DMC superfluid 3He dark matter detector. The bolometer, instrumented with nanomechanical resonators, will be sensitive to energy deposits from dark matter interactions. Events from radioactive decays and cosmic rays constitute a significant background and must be precisely modelled, using a combination of material screening and Monte Carlo simulations. However, the results presented here are of wider interest for experiments and quantum devices sensitive to minute heat leaks and spurious events, thus we present heat leak per unit mass or surface area for every material studied. This can inform material choices for other experiments, especially if underground operation is considered where the radiogenic backgrounds will dominate even at shallow depths.
Other Condensed Matter,Instrumentation and Detectors
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to evaluate and model the background events in superfluid helium - 3 (superfluid helium - 3) thermal detectors in direct dark matter detection experiments, especially those background events caused by radioactive decay and cosmic rays. Specifically, the goals of the paper include: 1. **Material screening**: Measure the radioisotope activity of common cryogenic materials through techniques such as high - purity germanium (HPGe) spectrometers to evaluate the radioactive background that these materials may introduce in the experiment. 2. **Heat - leak calculation**: Convert the measured radioactive activity into heat - leak power per unit mass or surface area to help select materials suitable for ultra - low - temperature experiments. 3. **Background simulation**: Use GEANT4 software to simulate in detail the energy deposition generated by the interaction between radioactive decay and cosmic rays and detector materials, thereby predicting the background level in the experiment. 4. **Optimization of experimental design**: Based on the above results, select the most appropriate materials and design strategies to minimize background interference and improve the sensitivity of dark matter detection. The focus of the paper is to ensure that the superfluid helium - 3 thermal detector can effectively detect low - mass dark matter interactions while accurately understanding and controlling the influence of background events. This is not only helpful for dark matter research but also of great significance for other quantum devices and experiments that require extremely low background noise.