Development of a Raman method to follow the evolution of coating thickness of pellets

Krisztina Nikowitz,Friederike Folttmann,Markus Wirges,Klaus Knop,Klára Pintye-Hódi,Géza Regdon Jr,Peter Kleinebudde
DOI: https://doi.org/10.3109/03639045.2013.795583
Abstract:Context: Although several methods have been investigated to measure the film thickness of tablets and its correlation with the dissolution behavior, much fewer such investigations exist for pharmaceutical pellets. Objective: To study the possibility of measuring the film thickness and predicting the dissolution behavior of pellets produced in different fluid bed equipments with Raman spectroscopy. Materials and methods: Pyridoxine hydrochloride-layered pellets were produced and coated in two different Strea-1 equipments. Raman spectra were collected and analysed to set up a calibration model based on the film thickness data calculated from Camsizer analysis results. Dissolution tests were done according to Ph. Eur. standards. Results: Raman spectroscopy proved to be a good tool in the measurement of film thickness. Polymer weight gain showed a linear correlation with film thickness but was a poor predictor of dissolution results below a threshold value. Conclusion: The Raman spectroscopic measurement of a small sample can provide accurate data of the film thickness. The investigation suggests that a threshold value might exist for the film thickness above which it can be used to judge future dissolution results.
What problem does this paper attempt to address?