Rotational Augmented Noise2Inverse for Low-dose Computed Tomography Reconstruction

Hang Xu,Alessandro Perelli
DOI: https://doi.org/10.1109/TRPMS.2023.3340955
2023-12-20
Abstract:In this work, we present a novel self-supervised method for Low Dose Computed Tomography (LDCT) reconstruction. Reducing the radiation dose to patients during a CT scan is a crucial challenge since the quality of the reconstruction highly degrades because of low photons or limited measurements. Supervised deep learning methods have shown the ability to remove noise in images but require accurate ground truth which can be obtained only by performing additional high-radiation CT scans. Therefore, we propose a novel self-supervised framework for LDCT, in which ground truth is not required for training the convolutional neural network (CNN). Based on the Noise2Inverse (N2I) method, we enforce in the training loss the equivariant property of rotation transformation, which is induced by the CT imaging system, to improve the quality of the CT image in a lower dose. Numerical and experimental results show that the reconstruction accuracy of N2I with sparse views is degrading while the proposed rotational augmented Noise2Inverse (RAN2I) method keeps better image quality over a different range of sampling angles. Finally, the quantitative results demonstrate that RAN2I achieves higher image quality compared to N2I, and experimental results of RAN2I on real projection data show comparable performance to supervised learning.
Image and Video Processing,Computer Vision and Pattern Recognition,Medical Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to maintain high - quality image reconstruction while reducing the radiation dose of patients in low - dose computed tomography (LDCT). Specifically, the paper proposes a new self - supervised method - Rotational Augmented Noise2Inverse (RAN2I) for low - dose CT image reconstruction. This method aims to train a convolutional neural network (CNN) without using accurate ground truth data, and improve the quality of CT images, especially under low - dose conditions, by enforcing the equivariant property of rotation transformation in the training loss function. The paper points out that although traditional supervised learning methods can effectively remove noise in images, they require accurate ground truth data, which usually requires additional high - dose CT scans, which is unrealistic in clinical applications. Therefore, an improved framework based on the Noise2Inverse (N2I) method, namely RAN2I, is proposed. This framework improves the image quality at different sampling angles by introducing the equivariant property of rotation transformation, especially in the case of sparse - view CT. Experimental results show that RAN2I is superior to N2I in both image quality and quantitative indicators, and its performance is comparable to that of supervised learning methods.