Precision Enhancement in Spatial Measurement by Introducing Squeezed Light into Weak Value Amplification

Chaoxia Zhang,Yongchao Chen,Gang Chen,Hengxin Sun,Jing Zhang,Kui Liu,Rongguo Yang,Jiangrui Gao
2024-08-10
Abstract:The precision enhancement is demonstrated in an optical spatial measurement based on weak value amplification (WVA) system and split-like detection, by injecting a TEM10 squeezed vacuum beam. It is the first time combining the WVA technique and squeezed beam injection to experimentally realize high-precision optical spatial measurement beyond the standard quantum limit. As a result, the precision enhancement of 1.3 times can be achieved at 500kHz by adding a squeezed beam in the vacuum input port of the Mach-Zehnder interferometer. The minimum measurable displacement is reduced from 1.08pm to 0.85pm and the corresponding minimum measurable tilt is reduced from 0.86prad to 0.67prad. Moreover, the spatial measurement at low-frequency band is also implemented and the SNR is improved 2dB at 4kHz. Our work provides an effective method to accomplish higher precision in optical spatial measurement, which has potential applications in gravitational wave interferometer calibration, super-resolution quantum imaging, etc.
Quantum Physics
What problem does this paper attempt to address?
The paper aims to address the issue of accuracy improvement in optical spatial measurements. Specifically, the authors have achieved high-precision optical spatial measurements that surpass the shot noise limit in a small tilt measurement system for the first time by combining Weak Value Amplification (WVA) technology and squeezed light injection. The main contributions are as follows: 1. **Weak Value Amplification Technology**: Utilizing WVA technology to amplify the signal and avoid detector saturation. 2. **Squeezed Light Injection**: Reducing noise levels to further improve the Signal-to-Noise Ratio (SNR). 3. **Beam-Splitting Detection System**: Employing a beam-splitting detection system characterized by large bandwidth, high gain, and low gap loss. Experimental results show that in both low-frequency (4 kHz) and high-frequency (500 kHz) ranges, the SNR is improved by 2 dB through the use of squeezed light injection, which translates to a 1.3-fold increase in accuracy. Specifically, with 2 dB squeezed light injection and a post-selection probability of 2.6%, the obtained displacement and tilt sensitivities are 4.96 fm/√Hz and 0.39 prad/√Hz, respectively. This work provides an effective method for achieving higher precision in quantum spatial measurements and has potential applications in fields such as gravitational wave interferometer calibration and super-resolution quantum imaging.