AstroSat observation of the magnetar SGR J1830$-$0645 during its first detected X-ray outburst

Rahul Sharma,Chetana Jain,Biswajit Paul,T. R. Seshadri
DOI: https://doi.org/10.1093/mnras/stad3026
2023-10-16
Abstract:We present here timing and spectral analyses of SGR J1830$-$0645 based on an AstroSat observation carried out on 2020 October 16, about a week after the onset of its first detected X-ray outburst. Using data taken with the Soft X-ray Telescope (SXT) and Large Area X-ray Proportional Counter (LAXPC), we have detected 0.9$-$10 keV coherent pulsations at a period of $\sim$10.4 s. The pulse profiles were single-peaked, asymmetric and consisted of minor peaks attributable to hotspots on the neutron star surface. The pulsed fraction evolved significantly with energy, increasing to energies around 5 keV with a steep drop thereafter. The 0.9--25 keV SXT--LAXPC energy spectrum is best described with two thermal components having temperatures $\sim$0.46 and $\sim$1.1 keV (emission radii of $\sim$2.4 and $\sim$0.65 km, respectively, assuming a distance of 4 kpc) along with a power-law component having a photon index of $\sim$0.39. We report the detection of 67 X-ray bursts having an average duration of $\sim$33 ms. The brightest burst lasted for about 90 ms and had a 3--25 keV fluence of $\sim 5 \times 10^{-9}$ erg cm$^{-2}$.
High Energy Astrophysical Phenomena
What problem does this paper attempt to address?
The problem that this paper attempts to solve is related to the timing and spectral characteristics of the magnetar SGR J1830−0645 during the first detected X - ray burst. Specifically, the researchers used the data from the AstroSat satellite to analyze the behavior of this magnetar during the observation on October 16, 2020, mainly focusing on the following aspects: 1. **Detection of Pulse Signals**: The researchers attempted to detect coherent pulse signals in the 0.9 - 10 keV energy range and determine their periods. 2. **Changes in Pulse Profiles**: Analyze the morphological changes of pulse profiles in different energy ranges and the trend of the pulsed fraction with energy. 3. **Spectral Analysis**: Study the spectral characteristics in the 0.9 - 25 keV energy range, including the contributions of thermal and non - thermal components. 4. **Detection and Analysis of X - ray Bursts**: Detect and analyze multiple short - time X - ray bursts that occurred during the observation, including their durations and fluxes. ### Specific Problems and Solutions 1. **Detection of Pulse Signals**: - Use the χ² maximization technique to determine the rotation period of SGR J1830−0645. - The results show that the rotation period is 10.415730 seconds with an error of 4×10⁻⁶ seconds. 2. **Changes in Pulse Profiles**: - Generate pulse profile diagrams in different energy ranges and find that the pulse profile in the low - energy section (0.9 - 3 keV) has an obvious asymmetric single - peak shape, while it is more complex in the high - energy section (6 - 10 keV). - The pulsed fraction reaches its maximum when the energy increases to about 5 keV and then drops sharply. 3. **Spectral Analysis**: - The 0.9 - 25 keV spectrum can be described by two blackbody radiation components plus a power - law component. - A possible 6.4 keV emission line is detected, but further verification is required to determine whether it is an instrumental effect. 4. **Detection and Analysis of X - ray Bursts**: - 67 X - ray bursts are detected, with an average duration of 33 milliseconds. - The brightest X - ray burst lasts about 90 milliseconds, and the flux in the 3 - 25 keV energy range is about 5×10⁻⁹ erg cm⁻². - The burst flux distribution conforms to a power - law function with an exponent of about 1.88. ### Main Conclusions - The pulse signal of SGR J1830−0645 in the 0.9 - 10 keV energy range is successfully detected, and the rotation period is 10.415730 seconds. - The pulse profile changes significantly with energy, and the pulsed fraction drops sharply after reaching its maximum at around 5 keV. - The 0.9 - 25 keV spectrum is composed of two blackbody radiation components and a power - law component, and a possible 6.4 keV emission line is detected. - 67 X - ray bursts are detected during the observation, with an average duration of 33 milliseconds, the brightest burst lasts 90 milliseconds, and the flux is about 5×10⁻⁹ erg cm⁻². These results are helpful for understanding the physical characteristics of the magnetar SGR J1830−0645 and the X - ray burst mechanism.