Rapid Scan White Light Two-dimensional Electronic Spectroscopy with 100 kHz Shot-to-Shot Detection

Asha S. Thomas,Vivek N. Bhat,Vivek Tiwari
2023-09-30
Abstract:We demonstrate an approach to two-dimensional electronic spectroscopy (2DES) that combines the benefits of shot-to-shot detection at high-repetition rates with the simplicity of a broadband white light continuum input and conventional optical elements to generate phase-locked pump pulse pairs. We demonstrate this through mutual synchronization between the laser repetition rate, acousto-optical deflector (AOD), pump delay stage and the CCD line camera, which allows rapid scanning of pump optical delay synchronously with the laser repetition rate while the delay stage is moved at a constant velocity. The resulting shot-to-shot detection scheme is repetition rate scalable and only limited by the CCD line rate and the maximum stage velocity. Using this approach, we demonstrate measurement of an averaged 2DES absorptive spectrum in as much as 1.2 seconds of continuous sample exposure per 2D spectrum. We achieve a signal-to-noise ratio (SNR) of 6.8 for optical densities down to 0.05 with 11.6 seconds of averaging at 100 kHz laser repetition rate. Combining rapid scanning of mechanical delay lines with shot-to-shot detection as demonstrated here provides a viable alternative to acousto-optic pulse shaping (AOPS) approaches that is repetition-rate scalable, has comparable throughput and sensitivity, and minimizes sample exposure per 2D spectrum with promising micro-spectroscopy applications.
Optics,Chemical Physics
What problem does this paper attempt to address?
The main objective of this paper is to demonstrate an improved two-dimensional electronic spectroscopy (2DES) technique that combines the advantages of shot-to-shot detection at high repetition rates with broadband white light continuum (WLC) input and conventional optical components to achieve rapid scanning of pump light delay. Specifically, the paper addresses the following key issues: 1. **Improving Data Acquisition Efficiency**: By synchronizing the laser repetition rate, acousto-optic deflector (AOD), pump delay stage, and CCD line array camera, the method achieves rapid scanning of pump light delay while maintaining the capability of shot-to-shot detection. This approach enhances data acquisition efficiency while maintaining a high repetition rate. 2. **Enhancing Signal-to-Noise Ratio**: Utilizing the shot-to-shot detection method effectively suppresses the 1/f component of experimental noise, thereby achieving a better signal-to-noise ratio at higher laser repetition rates. The paper reports a signal-to-noise ratio of 6.8 at a laser repetition rate of 100 kHz for samples with an optical density as low as 0.05. 3. **Simplifying Experimental Setup**: The proposed method uses conventional optical components instead of complex programmable acousto-optic pulse shaping (AOPS) technology, reducing cost and complexity while ensuring similar flux and sensitivity. 4. **Suitable for Microspectroscopy Applications**: Since the method can obtain high-quality 2DES data in a short time and reduce sample exposure time, it is highly suitable for microspectroscopy research requiring high spatial resolution. In summary, this paper proposes a novel 2DES technique aimed at providing a simple, efficient, low-cost, and high-repetition-rate scalable method to measure the ultrafast dynamics of complex systems.