Applying Energy Absorption Interferometry to THz direct detectors using photomixers

Ian Veenendaal,Edgar Castillo-Dominguez,Stephen J.C. Yates,Bram Lap,Willem Jellema
DOI: https://doi.org/10.1109/TTHZ.2023.3307568
2023-09-26
Abstract:Detector requirements for far infrared astronomy generally result in devices which exhibit a few-moded response to incident radiation. The sensitivity and spatial form of the individual modes to which such a detector is sensitive can be determined with knowledge of the complex valued cross-spectral density of the system, which we label the detector response function (DRF). A matrix representing the discretized cross-spectral density can be measured from the complex amplitudes of interference fringes generated by two identical sources as they are independently scanned through the field of view. We provide experimental verification of this technique using monochromatic THz beams generated by photomixers in which the relative phase is varied with fiber stretchers. We use this system to characterize the modal response of a single pixel from an array of microwave kinetic inductance detectors (MKIDs).
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The paper attempts to address the problem of how to characterize and measure the modal response of partially coherent terahertz (THz) detectors in far-infrared astronomy. Specifically, the authors propose a method based on Energy Absorption Interferometry (EAI) to measure the multimodal response characteristics of a single pixel, particularly the complex-valued correlation matrix of these responses. ### Background and Motivation 1. **Detector Requirements**: The requirements for detectors in far-infrared astronomical observations typically lead to devices exhibiting responses to a few modes of incident radiation. This response cannot be fully described by completely coherent or geometric optical models. 2. **Importance of Modal Response**: The modal response characteristics of detectors, including the number of modes, relative sensitivity, and their spatial forms, are crucial for validating detector performance. 3. **Frequency Dependence**: The modal response of the system is frequency-dependent, necessitating measurements across arbitrary frequency ranges. ### Solution 1. **Energy Absorption Interferometry (EAI)**: EAI is a general technique that can measure the coherent characteristics of any energy-absorbing structure. By introducing two independent source probes and scanning these probes within the field of view, the complex-valued correlation matrix of the system can be measured. 2. **Experimental Validation**: The authors conducted experimental validation using a monochromatic THz beam generator (such as an optical mixer). By adjusting the relative phase between the source probes using a fiber stretcher, they measured the amplitude and phase of the interference fringes. 3. **Data Processing**: By extracting the amplitude and phase of the interference fringes, a directly measured spatial correlation matrix of the system was constructed. This matrix can be decomposed into a set of orthogonal functions representing the coherent modes of the system. ### Experimental Setup 1. **Source Selection**: Two identical GaAs optical mixers were chosen as the light sources, driven by a pair of tunable near-infrared lasers. 2. **Phase Control**: The relative phase between the two source probes was adjusted using a fiber stretcher. 3. **Scanning System**: A motorized XYZ stage was used to independently position the optical mixers and their associated beam-forming optical elements. 4. **Test System**: The multimodal response characteristics of a single pixel from a large MKID array optimized for 850 GHz were validated. ### Results 1. **Complex-Valued Correlation Matrix**: The complex-valued correlation matrix of the system was successfully measured and reconstructed, describing the detector's sensitivity to various coherent modes. 2. **Modal Response**: By analyzing the correlation matrix, the primary modal responses of the detector and their spatial forms were determined. ### Significance 1. **Performance Validation**: This method provides an effective means for validating the performance of multimodal energy-absorbing detectors. 2. **Application Prospects**: It is suitable for the characterization and optimization of high-performance detectors for next-generation far-infrared space telescopes. In summary, the paper proposes a technique based on Energy Absorption Interferometry for characterizing and measuring the modal response of partially coherent THz detectors, providing important technical support for the development of future high-performance detectors.