The Simons Observatory: Cryogenic Half Wave Plate Rotation Mechanism for the Small Aperture Telescopes

K. Yamada,B. Bixler,Y. Sakurai,P. C. Ashton,J. Sugiyama,K. Arnold,J. Begin,L. Corbett,S. Day-Weiss,N. Galitzki,C. A. Hill,B. R. Johnson,B. Jost,A. Kusaka,B. J. Koopman,J. Lashner,A. T. Lee,A. Mangu,H. Nishino,L. A. Page,M. J. Randall,D. Sasaki,X. Song,J. Spisak,T. Tsan,Y. Wang,P. A. Williams
DOI: https://doi.org/10.1063/5.0178066
2023-09-26
Abstract:We present the requirements, design and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background (CMB) polarization experiment at Parque Astronómico Atacama in northern Chile that covers a wide range of angular scales using both small (0.42 m) and large (6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8~Hz, suppressing atmospheric $1/f$ noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to $\sim$50 K to reduce detector thermal loading. Under normal operation the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. The rotation angle is detected through an angular encoder with a noise level of 0.07$\mu\mathrm{rad}\sqrt{\mathrm{s}}$. During a cooldown, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
### What problems does this paper attempt to solve? This paper aims to solve several key challenges in the polarization measurement of the cosmic microwave background (CMB), especially the design, requirements, and performance evaluation of the Cryogenic Continuously Rotating Half - Wave Plate (CHWP) used in the Small Aperture Telescopes (SATs) of the Simons Observatory (SO). Specifically, this research mainly focuses on the following aspects: 1. **Suppression of atmospheric noise**: - The CMB polarization signal is very weak and is easily affected by atmospheric noise, especially the atmospheric 1/f noise in the low - frequency band. By using the CHWP to modulate the polarization state of the incident light at a frequency of 8 Hz, this kind of atmospheric noise can be effectively suppressed, thereby improving the detection sensitivity of the large - scale CMB B - mode polarization. 2. **Reduction of systematic errors**: - In traditional CMB polarization experiments, when using detector pairs with orthogonal polarization responses to separate linear polarization signals, any response mismatch will lead to intensity - to - polarization (I - to - P) leakage, contaminating the cosmological polarization signal. The use of the CHWP avoids the need for differential orthogonal detectors and reduces this kind of systematic error. 3. **Efficient observation and high - precision control**: - The paper describes in detail the mechanical design, thermal management, and data acquisition system of the CHWP, ensuring that it can operate stably in high - altitude and extreme environmental conditions, and has efficient rotation control and low - angle - encoding noise (0.07 µrad√s), thereby achieving long - term, high - precision observation. 4. **Wide - band coverage and multi - band operation**: - The Small Aperture Telescopes (SATs) of the SO need to cover multiple frequency bands (such as the intermediate - frequency bands of 93 GHz and 145 GHz, and the ultra - high - frequency bands of 225 GHz and 280 GHz) to separate the primordial B - mode polarization signal from the galactic foreground and other interference sources. The design of the CHWP must be able to meet the requirements of these different frequency bands. 5. **Modular design and maintainability**: - The paper emphasizes the modular design of the CHWP system, enabling each subsystem to be tested and iterated more frequently before being integrated into the complete SAT cryostat, thereby improving the reliability and maintainability of the system. In summary, this paper is committed to solving key problems such as atmospheric noise suppression, systematic error reduction, efficient observation, and multi - band operation encountered in CMB polarization measurement by developing and optimizing the Cryogenic Continuously Rotating Half - Wave Plate (CHWP) system, thus providing a more accurate tool for studying the early universe.