Zero-field optical magnetometer based on spin-alignment

Adil Meraki,Lucy Elson,Nok Ho,Ali Akbar,Marcin Koźbiał,Jan Kołodyński,Kasper Jensen
DOI: https://doi.org/10.1103/PhysRevA.108.062610
2023-08-24
Abstract:Optically-pumped magnetometers are an important instrument for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero-field. A novel approach is introduced, which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.
Applied Physics,Atomic Physics,Quantum Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the technical challenge of performing high - sensitivity magnetic measurement using spin - aligned atomic ensembles under zero - magnetic - field conditions. Specifically, the research focuses on developing an optical magnetometer based on spin - alignment to achieve accurate magnetic field measurement by evaluating the rotation of linearly polarized light when it passes through atomic vapor in a zero - magnetic - field environment. This method aims to improve the sensitivity and bandwidth of the magnetometer and reduce the influence of environmental magnetic fields and other interferences, thus providing more reliable data for applications such as medical imaging. ### Main contributions of the paper include: 1. **New zero - field magnetic measurement method**: A new method for detecting and correcting magnetic fields by using the polarization rotation of linearly polarized light passing through atomic vapor is proposed. 2. **Theoretical model and experimental verification**: Analytic expressions describing spin - alignment and optical detection signals are derived, and these theoretical predictions are verified experimentally. 3. **Performance characterization**: The sensitivity and bandwidth of the magnetometer are characterized by analyzing the detected polarization - rotation signals. 4. **Practical applications**: The potential of this magnetometer in medical applications is demonstrated, and synthetic cardiac signals are successfully detected. ### Key technical points: - **Spin - alignment**: Atomic spins are aligned using linearly polarized light instead of the traditional spin - orientation method. - **Polarization rotation**: Changes in the magnetic field are detected by measuring the rotation angle of linearly polarized light when it passes through atomic vapor. - **Zero - field conditions**: Measurements are carried out under zero - magnetic - field conditions to eliminate the influence of environmental magnetic fields and other interferences. ### Experimental setup: - **Light source**: A laser with a wavelength of 895 nm is used, which is resonant with the D1 transition of cesium atoms from F = 4 to F'= 3. - **Magnetic shielding**: Four - layer μ - metal magnetic shielding is used to reduce the interference of external magnetic fields. - **Magnetic field control**: Magnetic fields are applied in the x, y, and z directions by three sets of coils respectively for correcting and scanning the magnetic field. - **Signal detection**: A balanced photodetector and polarization measurement techniques are used to detect the polarization - rotation signal. ### Results and discussion: - **Static magnetic field correction**: By systematically scanning and adjusting the applied magnetic field, the total static magnetic field is successfully corrected to a level close to zero. - **Zero - field resonance**: Under zero - field conditions, zero - field resonance with a Lorentzian line shape is observed through absorption measurement. - **Polarization rotation measurement**: It is shown that under zero - field conditions, the magnetometer has high sensitivity to magnetic field changes along the x - direction. - **Bandwidth and sensitivity**: By applying sinusoidal magnetic fields with different frequencies, the bandwidth and sensitivity of the magnetometer are characterized. The results show that its noise floor is approximately 0.3 pT/√Hz (in the range of 10 Hz to 100 Hz). In conclusion, by introducing the spin - alignment - based zero - field magnetic measurement method, this paper not only improves the sensitivity and bandwidth of the magnetometer but also provides new possibilities for its practical applications in fields such as medical imaging.